Service call that the Outdoor Unit was making a loud buzzing noise. Spoke with homeowner upon arrival about issue. Turned AC on and proceeded outside to check unit. Found that the Fan Lid Cover was vibrating and causing the Buzzing Noise. Adjusted Position of Fan Blade on the Motor Shaft and reinstalled the Fan Lid onto the Unit. Put system in operation to test. Monitored system while it was running to ensure that the noise had ceased. No excessive noise was coming from the unit at this time. The Replacement Motor is larger in size than the original motor. If the noise returns then the recommendation would be to install the OEM Condenser Motor with a new Fan Blade. The outdoor unit is not completely level which cause the system to vibrate more due to not being balanced.