520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.


Job Locations
for kennett square, pa


Map of Kennett Square PA
Joseph D.

Joseph D.


Job Checkin

Completed PECO Tune Up. Equipment 3 Ton communicating Carrier Heat pump with 20KW electric heat kit. 18 years old Homeowners said electric bill $600+ dollars. However when they talked to previous homeowner they confirmed that this was the average bill. Carrier thermostat does have the option to run “Heat Pump only” as well as “System Control” and “electric heat only”. There is no way to set outdoor temp lockout for electric heat. Controls are carrier communicating. I cannot offer Ecobee or smart thermostat as they are not compatible. Setting thermostat to “heat pump only”will result in some savings. There is no drain protection. Left email estimates. Left email estimate for intermatic surge protector for outdoor equipment circuit and ECM surge protector for blower motor. Bypass humidifier damper is missing which is needed for summer. Left estimate. There is a propane furnace with AC for master bedroom area. (added as an addition to house in 2008). Temperature rise in heat pump