Installed new amana 2 stage gas furnace with single stage 3 1/2 ton a/c system. Installed furnace on legs with new 24x10 return drop. Adapted to metal supply plenum. Sealed exsisting condensate hole in cement. Added condensation pump and pumped water into wash sink next to furnace. Installed new reme halo in supply plenum. Tested furnace in both heating and cooling modes. System is working fine at time of install.