Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Performed heating maintenance, replaced standard air filter. Inspected heat exchanger. Cleaned flame sensor. Checked voltage, amperage and electrical connections, measured capacitor values ok. Started gas furnace, tested limit and safety switches. Performed combustion test. Checked operation and temperature rise.