Performed heating maintenance on gas furnace, replaced air filter, inspected heat exchanger. Cleaned burners and pilot burners. Checked voltage, amperage and electrical connections, measured capacitor values ok. Started gas furnace, performed combustion test. Tested limit and safety switch’s. Checked operation and temperature rise.