1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Local Reviews
for dyer, in

Rated 5.0 out of 5 stars based on 2 customer reviews

Estimate


Response from Trenchless Innovations Inc.:

Thank you for your five-star review, Gregory! We are delighted that you chose Trenchless Innovations for your underground air duct inspection. We hope the results of our report point you to a solution to your air duct problems. Please don't hesitate to reach out if you have any further questions. We appreciate your business!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

The technicians were awesome, on time, neat and very knowledgeable.


Response from Trenchless Innovations Inc.:

Thank you for your review, Nancy! We are so happy to hear you had a great experience with our team and we hope you're enjoying the many benefits that our air duct lining provides. Thank you for choosing Trenchless Innovations for your air duct repair!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dyer, in

Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are a combination of PVC and metal ducts that are allowing sand to enter the system where the metal is rusting. Plenum under furnace is also very rusted. Suggest spin cast mortaring metal then spray lining entire system with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Sewer cleanout installation service call. A 4’ hole was dug on the side of the warehouse to expose the 4” cast iron sewer. The old cleanout was removed and 2 4” wyes were installed. Will be returning to descale the cast iron under the building. Work was approved by village and hole was covered up.


John R.

John R. Job Checkin

Video sewer inspection service call. 10-4-2023: Did a video inspection of 230’ of 4” from outside 4” pvc clean out 100’ upstream, also from inside 4” pvc floor clean out 120’ upstream. Getting quote to customer to descale all 350’ of 4” cast outside clean out needs to be excavated 5’ deep to work/descale from open hole/pipe.


Kevin W.

Kevin W. Job Checkin

Sewer lining service call. 10-2-2023: lined sewer from open hole in kitchen/ bathroom 18’ downstream of 4” cast starting liner in 4” PVC and ending liner in 4” cast at cast-clay connection.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings and connections that are very rusted and deteriorated. Suggest spin cast mortaring the metal fittings then spray lining system with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings and connections that are rusting and allowing sand to enter into the system. There is also heavy sand in the plenum. Suggest spin cast mortaring the spray lining with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the heavily rusted underground duct work.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with asbestos with metal fittings and connections that are very rusted and allowing sand to enter the system. There is also one ducts that is dropped. Suggest installing a sewer patch over that area then spin cast mortaring the metal fittings then spray lining ducts with Duct Armor duct lining material.


Josh R.

Josh R. Job Checkin

We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings. Sand getting into ducts from plenum and metal fittings. Suggest spin cast mortaring the fittings then spray lining ducts with Duct Armor duct lining material.


Kevin W.

Kevin W. Job Checkin

We are cleaning all the underground duct work, applying our trenchless cast mortar to all the metal fittings, and sealing the entire underground duct work with our duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Customer had a sewer backup and water leaked into the ducts. Ducts have standing water. Need to dry out ducts then spray line to encapsulate the ducts with Duct Armor duct lining material because of sewer contamination.


Kevin W.

Kevin W. Job Checkin

Cleaned all deteriorated underground duct work. Applied trenchless cast mortar to all underground duct work to give pipe a strong structure.


Kevin W.

Kevin W. Job Checkin

Cleaned and restructured all the underground duct work under a slab home. Then applied two applications of our duct lining product to seal and encapsulate all the underground duct work.


Kevin W.

Kevin W. Job Checkin

Cleaned sand and debris from all underground ductwork. Applied spin cast mortar to underground ducts to give them a strong structure.