Thank you for your five-star review, Gregory! We are delighted that you chose Trenchless Innovations for your underground air duct inspection. We hope the results of our report point you to a solution to your air duct problems. Please don't hesitate to reach out if you have any further questions. We appreciate your business!
The technicians were awesome, on time, neat and very knowledgeable.
Response from Trenchless Innovations Inc.:
Thank you for your review, Nancy! We are so happy to hear you had a great experience with our team and we hope you're enjoying the many benefits that our air duct lining provides. Thank you for choosing Trenchless Innovations for your air duct repair!
Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings and connections that are very rusted and deteriorated. Suggest spin cast mortaring the metal fittings then spray lining system with Duct Armor duct lining material.
Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings and connections that are rusting and allowing sand to enter into the system. There is also heavy sand in the plenum. Suggest spin cast mortaring the spray lining with Duct Armor duct lining material.
We are applying the second application of our rubberized duct lining material to all of the heavily rusted underground duct work.
Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with asbestos with metal fittings and connections that are very rusted and allowing sand to enter the system. There is also one ducts that is dropped. Suggest installing a sewer patch over that area then spin cast mortaring the metal fittings then spray lining ducts with Duct Armor duct lining material.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
Televised ducts under slab floor. Ducts are concrete ducts with metal fittings. Sand getting into ducts from plenum and metal fittings. Suggest spin cast mortaring the fittings then spray lining ducts with Duct Armor duct lining material.
We are cleaning all the underground duct work, applying our trenchless cast mortar to all the metal fittings, and sealing the entire underground duct work with our duct lining material.
Televised ducts under slab floor. Customer had a sewer backup and water leaked into the ducts. Ducts have standing water. Need to dry out ducts then spray line to encapsulate the ducts with Duct Armor duct lining material because of sewer contamination.
Cleaned all deteriorated underground duct work. Applied trenchless cast mortar to all underground duct work to give pipe a strong structure.
Cleaned and restructured all the underground duct work under a slab home. Then applied two applications of our duct lining product to seal and encapsulate all the underground duct work.
Cleaned sand and debris from all underground ductwork. Applied spin cast mortar to underground ducts to give them a strong structure.
Video inspection of underground air ducts. Ducts are concrete possibly Transite with asbestos with metal couplings and fittings. Metal fitting and the plenum under the furnace are heavily rusted and deteriorated. Suggest restoring structure black to fittings by spin cast mortaring a new concrete pipe in those areas. After the structure has been restored the system should be spray lined with Duct Armor duct lining material.