Existing 20 gallon pressure tank has a leak in the bladder which causing pressure issues throughout the home. Air in the tank was 0 psi. Existing well pump is drawing 2.7 amps. This amp draw is a little low but the pump seems to be working just fine at this time. Homeowners purchased a 20 gallon pressure with no tank tee, I highly recommend they go back out and purchase a 35-45 gallon pressure since they have a barn with yard hydrants. A bigger pressure tank will give a longer range of water pressure and make the existing well pump happier because the pump won’t run as much. Also recommended theymcontact mermaid water to service the existing kinetico water softener. These units should be serviced once a year. Homeowners is going to vamac plumbing supply tonight to purchase a 35 gallon pressure tank and 1” tank tee kit. Will return tomorrow morning to complete proposed work. Put the correct air pressure back into the tank so they would have better water pressure for the time being. Sen