6178 Energy Road
Bealeton, VA 22712
540-439-6544

Job Locations
for delaplane, va


Map of Delaplane VA
Matthew W.

Matthew W.


Job Checkin

Excavation and backfill for the replacement of existing pitless adapter for well pump. This will involve hand digging to expose pitless adapter, pulling of well pump for removal of pitless adapter and installation of new. Testing new and backfilling to rough grade only. Seed and straw disturbed area. Installation of new well cap. - technician arrived, hand dug to expose piping to well casing. Found pitless adapter cracked. Pulled well pump roughly 20 feet out of casing, removed old pitless adapter and installed new. Connected new pitless adapter to existing water line with coupling and short piece of new 1 inch black poly. Installed new compression well cap as well since existing was no longer sealing around casing. Turned water on and tested. At first, house had great water pressure. It dwindled down to a trickle. Went to well tank in basement and found a 2x10 canister filter on the INLET side of well tank. This is not the recommended spot for installation of a sediment filter. Filte