6850 West 47th Tr
Mission, KS 66203
(913) 268-6822

Job Locations
for leawood, ks


Map of Leawood KS
Jeremy  C.

Jeremy C.


Job Checkin

4/26/24 Sent out today to Todd and Katie’s in regards to a backdrafting water heater. Upon arrival I was greeted by Todd who I went over the purpose of today’s visit with and answered any immediate questions they had to help set expectations. Other than the water heater they mentioned an issue with a low flow faucet in the kitchen. VITAL READINGS: -Total Dissolved Solids (cold): 298 ppm -Total Dissolved Solids (hot): 499 ppm -Water Pressure Static: 75 psi -Water Pressure Faucet Open: 75 psi (w/ prv) -Water Temp Setting: 120 F -Water Temp Output: 122 F -Water Hardness: 7 grains of calcium per gallon -Water Quality: none -Water Heater: 2022 gas 50 gal w/ expansion tank -Water Lines: copper, pex -Drain Lines: pvc OBSERVATIONS: -back drafting and co detectors going off -high disloved solids in lines -low flow at kitchen faucet Solutions : **MUST** customer supplied kitchen faucet **SHOULD** supplied kitchen faucet + water sediment filter **IMPROVED** LBA supplied kitchen faucet + c