Job Checkin

4/09/24 Sent out today to Tim’s in regards to their annual membership plumbing inspection. Upon arrival I was greeted by Tim who I went over the purpose of today’s visit with and answered any immediate questions they had to help set expectations. VITAL READINGS: -Total Dissolved Solids (cold): 234 ppm -Total Dissolved Solids (hot): 458 ppm -Water Pressure Static: 65 psi -Water Pressure Faucet 63 Open: psi (w/ prv) -Water Temp Setting: -Water Temp Output: 125 F -Water Hardness: 8 grains of calcium per gallon -Water Quality: none -Water Heater: 2018 gas Rudd, expansion tank, 1/4 turn shutoff (installed by LBA) -Water Lines: copper -Drain Lines: ABS OBSERVATIONS: BASEMENT (main entrance, pressure regulator, laundry, water heater) -water heater from 2018, expansion tank, 1/4 turn shut off -newer main entrance valve, and pressure regulator MAIN FLOOR (kitchen, 2 bathrooms) -older style shutoffs in kitchen (2) -new shutoffs on both toilets -no shutoffs under vanity sinks (4) -newer t