*)*)&)*)&)*))*)*)*)&)*)*)*)*))*)*)*)*))*)*)*)*)*)* Do not bill for fuses that are on the p.o. For this job. *)*)&)&)*)*’gmjgjgjgjgjgjtjgjf**&(&/&/$($($(($($($(&(& Today (12/2/25) a new gas valve was picked up and brought on-site. The valve was changed and the furnace was checked for electrical and mechanical functions. The furnace returned to normal function after the repair was completed. The flame sensor was removed and cleaned today as part of the heating check. The amp draws are in range, motor bearings ok, flame sensor in range and the furnace cycles properly into and out of heat mode. The estimate for today’s work is included below for reference. Thank you, Jon Tech notes: Goodman 90% nat gas furnace (twinned) Inducer motor 1.7A (rated 2.8) Blower motor amps 6.2 (rated <8) Temp rise 46 (120-74) rated: 40-70 New gas valve Control voltage 25.6acv ————————————————————————————————-, This is a time plus material estimate for the replacement of the gas v