Great Service Technician

JJ, was very polite and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for buckner, mo

Chase P.

Chase P. Job Checkin

System was not running when I arrived. I found the thermostat was set to only one stage of heat and cool instead of two stage which would match the system. I found the W-2 wire not hooked up at the thermostat as well. I fixed wiring and reprogrammed the thermostat. Heat pump kicked on, but the heat strips did not. I went through the system and checked all the wiring and separated the wiring to test voltage. Voltage from the thermostat was reading only 14 Volts. I changed out the thermostat and then the system ran in both stages for heat strips and heat pump. System is operating as it should departure.


Chase P.

Chase P. Job Checkin

Heat pump was shutting off after only five minutes of operation when I arrived, which was causing the indoor heat kit to run way too long. After inspecting the full system, I found that a setting needed adjusted on the outside unit and after adjusting that to the correct setting The heat pump ran for over 30 minutes without any issues.


Johann A.

Johann A. Job Checkin

Went for a heating tune up. Inspected heat strips no wear and tear. As well for evaporator coil is clean. Heat strips and blower are passing for amperage. Did notice condenser unit was off. A wire wasn’t making full contact tightened it. Refrigerant charge is passing. Temp split passes on system. System is up and running before departure. Thank you for choosing LBA services-Johann


Patrick  K.

Patrick K. Job Checkin

Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Verified operation of all mechanical and electronic components of the furnace. Found that the system is not wired for heat pump operation. Checked blower for cleanliness and to see if there is any play in the bearings. Found that the blower wheel is coated in dust debris. Checked systems heat exchanger to ensure proper venting of flue gas. Performed an electronic gas leak search. Found a fitting close to the water heater that is leaking gas. Furnace is operational at this time.


JJ H.

JJ H. Job Checkin

Went for an AC maintenance today. Filter is clean. Temperature split between the supply and return duct passed. Evaporator coil is clean and rust free. Outside system is clean. Refrigerant pressures met factory specifications. Compressor and fan motor amperage passed. Capacitor passed as well. Thank you for choosing LBA services!


JJ H.

JJ H. Job Checkin

Went for an AC inspection today. Changed the filter. Temperature split between the supply and return duct passed. Evaporator coil is clean and rust free. Outside system got washed. Refrigerant pressures met factory specifications. Compressor and fan motor amperage was high, after washing unit, both components are running at desired level. Capacitor passed as well. Thank you for choosing LBA services!


JJ H.

JJ H. Job Checkin

Replaced defrost board. System is up and cooling. Thank you for choosing LBA services!


Graham W.

Graham W. Job Checkin

After checking the system and teaming up with Robbie, we believe the outdoor control board is the issue.


Joe K.

Joe K. Job Checkin

Replace condenser and coil. Add to Dragonette.


Robby M.

Robby M. Job Checkin

Customer called for no cool. Upon arrival customer turned unit on for technician to listen to. Compressor is internally damaged and making very loud noise and not moving refrigerant. Trying to get distributor to honor manufacturer warranty on unit replacement as this model is discontinued. Customer is aware we are actively trying to find him a suitable replacement and will contact him once we know what is available and what we can do. We did deliver some temporary units to customer for the mean time.


Patrick  K.

Patrick K. Job Checkin

Arrived to do a performance maintenance. Set system for cooling. Measured the systems static pressure measured a temperature split between return and supply air. Checked interior of the furnace for cleanliness. Went outside and verified refrigerant levels. Verified operation of all electronic and mechanical components. Rinsed coil free of debris. Spoke with homeowner about the system. Air conditioning system still looks brand new and is operational at this time.


Joe K.

Joe K. Job Checkin

Installed heat strips. Installed humidifier and UV light. Cycled and tested all components. Changed breakers to proper size. Unit is operational at this time.


Joe K.

Joe K. Job Checkin

Estimated


Tyler R.

Tyler R. Job Checkin

Upon arrival I began the AC tune up. Everything checked out within manufacturer specifications. Static pressure was at .7 on a .8 max system. All equipment was installed by IT. If you have any questions or concerns please feel free to contact us! Your LBA Technician, Tyler Rickard P.S. No payment was due today, it was covered with your membership. Have a great weekend to come!


Jared B.

Jared B. Job Checkin

Sold 3 ton Standard AHU & HP with new humidifier, IAQ 3000, and new drop and air box $14,249.82