Went for an AC inspection today. Changed the filter. Temperature split between the supply and return duct passed. Evaporator coil is clean and rust free. Outside system got washed. Refrigerant pressures met factory specifications. Compressor and fan motor amperage was high, after washing unit, both components are running at desired level. Capacitor passed as well. Thank you for choosing LBA services!
Replaced defrost board. System is up and cooling. Thank you for choosing LBA services!
After checking the system and teaming up with Robbie, we believe the outdoor control board is the issue.
Replace condenser and coil. Add to Dragonette.
Customer called for no cool. Upon arrival customer turned unit on for technician to listen to. Compressor is internally damaged and making very loud noise and not moving refrigerant. Trying to get distributor to honor manufacturer warranty on unit replacement as this model is discontinued. Customer is aware we are actively trying to find him a suitable replacement and will contact him once we know what is available and what we can do. We did deliver some temporary units to customer for the mean time.
Arrived to do a performance maintenance. Set system for cooling. Measured the systems static pressure measured a temperature split between return and supply air. Checked interior of the furnace for cleanliness. Went outside and verified refrigerant levels. Verified operation of all electronic and mechanical components. Rinsed coil free of debris. Spoke with homeowner about the system. Air conditioning system still looks brand new and is operational at this time.
Installed heat strips. Installed humidifier and UV light. Cycled and tested all components. Changed breakers to proper size. Unit is operational at this time.
Upon arrival I began the AC tune up. Everything checked out within manufacturer specifications. Static pressure was at .7 on a .8 max system. All equipment was installed by IT. If you have any questions or concerns please feel free to contact us! Your LBA Technician, Tyler Rickard P.S. No payment was due today, it was covered with your membership. Have a great weekend to come!
Sold 3 ton Standard AHU & HP with new humidifier, IAQ 3000, and new drop and air box $14,249.82
Arrived to evaluate a system a homeowner would like to replace. Homeowner mentioned that the system is still working but is making a good bit of noise. Found that the system is 30 years old. Opened up the system and found that the interior of the equipment is heavily coated in bacterial growth. Performed a static pressure test and found that the system is flowing air very well. Considering the amount of bacterial growth and dust in the system, would recommend replacement considering the high cost of cleanings.