5558 Berkshire Valley Road STE 6
Oak Ridge, NJ 07438
(973) 838-3200

Our Top Cities


Local Reviews
for dumont, nj

Rated 5.0 out of 5 stars based on 1 customer reviews

Beyond Excellent Service

Jerry and Cody arrived on time, they were courteous, professional, polite and efficient. These gentlemen worked their magic so that I had a new a/c system installed and working in what seemed like no time at all. They did not leave my home until the knew that everything was back up and running and I didn't have to clean up after them! It's great working with a company that has great service and amazing employees! Thanks Jerry and Cody, you made my day and my summer!


Response from Climate Plus, LLC:

Thank you for your review. We are happy to hear that Jerry and Cody provided you with beyond excellent service. Their punctuality, professionalism, and efficiency are qualities we strive for in all our team members. We're delighted that they were able to install your new AC system seamlessly and leave your home in great condition. It's customers like you who make our work truly rewarding. Thank you for choosing us! Best Regards, Joseph

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for dumont, nj

Joseph C.

Joseph C. Job Checkin

Perform the spring maintenance for one AC system, confirm that all the filters had been replaced and were cleaned. Chemically cleaned the outdoor condenser and remove all the debris from inside of the condenser base. Installed my wireless probes and sensors and started up the system, performed a full measure quick scan on the system and confirm that it is operating and cooling properly. Took all the required photos and uploaded a copy of the completed report to be emailed along with this invoice.

Perform the spring maintenance for one AC system, confirm that all the filters had been replaced and were cleaned. Chemically cleaned the outdoor condenser and remove all the debris from inside of the condenser base. Installed my wireless probes and sensors and started up the system, performed a full measure quick scan on the system and confirm that it is operating and cooling properly. Took all the required photos and uploaded a copy of the completed report to be emailed along with this invoice.

Joseph C.

Joseph C. Job Checkin

Received a call that the second floor unit was locking out, on arrival I found the reset for compressor one was tripped. I reset it and cycled the unit, confirmed that the first Bank of compressors came on and continue to allow you to recovery. Checked operation for all the connector fan motors, the motors are working however I noticed that condenser fan contactor 1K8, which controls condenser fan motors number 282 and number 283 would disconnect during operation causing the unit head pressure to get excessively high which is then causing the compressor safety to trip. I went through all of the programming and ran it in manual test mode and found that it does work in manual test mode.

Received a call that the second floor unit was locking out, on arrival I found the reset for compressor one was tripped. I reset it and cycled the unit, confirmed that the first Bank of compressors came on and continue to allow you to recovery. Checked operation for all the connector fan motors, the motors are working however I noticed that condenser fan contactor 1K8, which controls condenser fan motors number 282 and number 283 would disconnect during operation causing the unit head pressure to get excessively high which is then causing the compressor safety to trip. I went through all of the programming and ran it in manual test mode and found that it does work in manual test mode.

Joseph C.

Joseph C. Job Checkin


Joseph C.

Joseph C. Job Checkin

Perform the maintenance for the gas furnace, replace the customer supplied air filter. Installed a new inline water filter for the humidifier, cleaned out the water tray and confirmed operation of the humidifier. I need to return with a replacement pad. Start up the furnace and check the operation, confirmed operation of the gas valve and of the safety controls. Checked all plugs and electrical connections on the circuit board, and confirmed proper operation in ramping up and down of the blower motor and draft inducer. The furnace is operating properly.

Perform the maintenance for the gas furnace, replace the customer supplied air filter. Installed a new inline water filter for the humidifier, cleaned out the water tray and confirmed operation of the humidifier. I need to return with a replacement pad. Start up the furnace and check the operation, confirmed operation of the gas valve and of the safety controls. Checked all plugs and electrical connections on the circuit board, and confirmed proper operation in ramping up and down of the blower motor and draft inducer. The furnace is operating properly.

Gerard E.

Gerard E. Job Checkin

For expert residential AC repair and installation services, trust Climate Plus LLC. Our team specializes in fixing common issues like faulty compressors, refrigerant leaks, and clogged filters. Contact us for fast and reliable solutions to keep your home cool and comfortable.


Jack B.

Jack B. Job Checkin

Bad pilot light assembly on Ruud gas fired furnace

Bad pilot light assembly on Ruud gas fired furnace