Arrived on site to check out the system for no cooling, I found that the disconnect was off for the system. I performed a continuity test on the compressor windings and checked it for ground, pressure checks out okay. I installed my pressure probes and found that the system is flat out of refrigerant and I recommend performing a leak test. I will send a quote for a nitrogen leak test and upon approval I will perform the link test immediately.
Perform the maintenance for the gas hot air furnace in the attic, removed the filter and picked up and replaced it with a new 20x25x4 pleated filter. Removed and cleaned the flame sensor, checked all electrical plugs and connections, confirmed operation of the blower motor, draft inducer motor, and gas valve. Cycled the furnace and confirmed proper operation of the heating cycle, the furnace is operating properly.