Arrived onsite for issues with cooling. Homeowner explained system didn’t start. He had to reset breakers to get it to restart. Performed diagnostic. System started and refrigerant pressures are good in relation to outside temperature. Found a fault in the voltage enhancement system. Outside manufacturer’s specification. Believe the condenser fan motor was failing to start then the compressor was over heating and going off on high head pressure. Replace faulty part and confirmed operation of the system
Arrived onsite to repair broken condensate drain. Removed broken piece and replaced with new drain
Arrived onsite for maintenance for one gas fired boiler. Requested the customer turn on the thermostats up to heat and confirm operation of the boiler and each zone valve. Turned the boiler off and cleaned all burners. Cleaned electrical compartment. performed a visual inspection of all electrical and inspected all external water components such as the exp tank, fill valve, backflow preventer and the circulator pump. Confirmed everything is operating and heating properly at this time.
Experience the convenience of an EPP 1C-Maintenance arrival in the late afternoon or evening. Our customer-focused service allows you to change your own filters while our team ensures a top-notch maintenance check. Make the most of your time by scheduling ahead!
Annual heating tuneup on SlantFin Gas Fired Boiler