Rated 5.0 out of 5 stars based on 1 customer reviews

beyond excellent service!

Gerry and Cody came to do work in my office and they not only installed the new part without disturbing my office but they cleaned up afterwards. They were helpful, explained everything and so very professional! so Glad I called Climate Plus and these gentlemen showed up!


Response from Climate Plus, LLC:

Thank you so much for your glowing review! We're thrilled to hear that Gerry and Cody provided such outstanding service during their visit. Their attention to detail, professionalism, and respect for your workspace are exactly what we strive for at Climate Plus. We're so glad you called us, and we're delighted that Gerry and Cody could assist you. If you ever need anything in the future, we're just a call away! Best regards, The Climate Plus Team

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for englewood, nj

Gianna M.

Gianna M. Job Checkin

Arrived onsite found two front RTUs locked out. Power reset both system and they started cooling again.

Arrived onsite found two front RTUs locked out. Power reset both system and they started cooling again.

Jack B.

Jack B. Job Checkin

Arrived onsite with issues on both AC systems. Attic condenser system was off at the breaker. Reset the breaker and system started.


Joseph C.

Joseph C. Job Checkin

Received a call that the unit that serves the bedrooms which is the furnace in the basement with the condenser in the back of the house was not cooling, upon arrival I found that the connector was running and the suction line was frozen. I open the coil in the basement and confirm that the evaporator is also frozen, I switched the cooling to off and left the fan in the on position. I will return in the morning to start the system up and perform a measure quick scan on it.


Joseph C.

Joseph C. Job Checkin

Received a call that the unit that serves the bedrooms which is the furnace in the basement with the condenser in the back of the house was not cooling, upon arrival I found that the connector was running and the suction line was frozen. I open the coil in the basement and confirm that the evaporator is also frozen, I switched the cooling to off and left the fan in the on position. I will return in the morning to start the system up and perform a measure quick scan on it.


Jack B.

Jack B. Job Checkin

Received a call that the second floor unit was locking out, on arrival I found the reset for compressor one was tripped. I reset it and cycled the unit, confirmed that the first Bank of compressors came on and continue to allow you to recovery. Checked operation for all the connector fan motors, the motors are working however I noticed that condenser fan contactor 1K8, which controls condenser fan motors number 282 and number 283 would disconnect during operation causing the unit head pressure to get excessively high which is then causing the compressor safety to trip. I went through all of the programming and ran it in manual test mode and found that it does work in manual test mode, however in automatic mode it is not pulling the contactor in when it is supposed to. This is more than likely a circuit board fault which would require a new main control board, to temporarily rectify the situation I linked condenser fan contact or 1K8 into the low voltage circuit of contactor 1K7.


Joseph C.

Joseph C. Job Checkin

Received a call that the second floor unit was locking out, on arrival I found the reset for compressor one was tripped. I reset it and cycled the unit, confirmed that the first Bank of compressors came on and continue to allow you to recovery. Checked operation for all the connector fan motors, the motors are working however I noticed that condenser fan contactor 1K8, which controls condenser fan motors number 282 and number 283 would disconnect during operation causing the unit head pressure to get excessively high which is then causing the compressor safety to trip.


Joseph C.

Joseph C. Job Checkin

Received a call that the new AC system that was installed last year which does the kitchen, living room and family room area was not cooling, upon arrival I cycled the system and found that it was going out on the low pressure control. I bypassed the low pressure control and allowed the system to operate, I attempted to add refrigerant to see if I could get the suction pressure to come up and I found that my sub cooling was high and my superheat is high, this is a sign of a failed TXV. We will need to get a new TXV valve and we will have to replace it. The parts are covered under warranty, we will need to verify if there is an extended labor program on the equipment.


Jack B.

Jack B. Job Checkin

Arrived onsite for ac maintenance on 2 systems. New homeowner so initially discussed the history of the heating and cooling systems. Homeowner also is inquiring about having the ducts cleaned because the home is currently being renovated.

Arrived onsite for ac maintenance on 2 systems. New homeowner so initially discussed the history of the heating and cooling systems. Homeowner also is inquiring about having the ducts cleaned because the home is currently being renovated.

Joseph C.

Joseph C. Job Checkin

Arrived onsite for a leak from the RTU AC condensate system. Observed water coming from the pressure relief flaps. Cleared the condensate trap and blew out the condensate line, removing debris. Primed the trap and confirmed proper operation, with no further water observed leaking from the pressure flaps. Advised the customer that if the issue persists, the unit may need a deep clean of the condensate tray and an inspection for possible leaks.

Arrived onsite for a leak from the RTU AC condensate system. Observed water coming from the pressure relief flaps. Cleared the condensate trap and blew out the condensate line, removing debris. Primed the trap and confirmed proper operation, with no further water observed leaking from the pressure flaps. Advised the customer that if the issue persists, the unit may need a deep clean of the condensate tray and an inspection for possible leaks.

Joseph C.

Joseph C. Job Checkin

Don't let water damage ruin your property! Our team is available to fix leaks on the 3rd floor before your upcoming fire inspection on 9/16. Trust our expert service to ensure a safe and secure building.

Don't let water damage ruin your property! Our team is available to fix leaks on the 3rd floor before your upcoming fire inspection on 9/16. Trust our expert service to ensure a safe and secure building.

Joseph C.

Joseph C. Job Checkin

Arriving in the afternoon on 9/13? Ensure to check for clogged drain line from reported leaks on 3rd floor. Our team will promptly address this issue and provide expert service.


Joseph C.

Joseph C. Job Checkin

On 9/10, we are returning to replace a rotted section of the line as per Joe's message in teams. Trust our experts to provide efficient and reliable service to restore your plumbing system.


Gerard E.

Gerard E. Job Checkin

Went out to a commercial client who was experiencing high humidity levels. Found the damper was stuck open, causing the issue. We installation a new damper to help regulate humidity levels.


Joseph C.

Joseph C. Job Checkin

Looking for quality HVAC services? Visit Climate Plus LLC on the 2nd floor for all your heating and cooling needs. Contact us today for top-notch service and solutions.


Gianna M.

Gianna M. Job Checkin

For expert AC repair and installation of central air conditioning units, look no further than Climate Plus LLC. Our experienced technicians will ensure your home stays cool and comfortable all year round. Contact us for all your residential AC needs.