Received a call that the Coleman unit in the attic on the right hand side of the house was not cooling, upon arrival I found that the air filter was plugged solid. Removed the filter media and replaced it with the one that was on top of the air handler, I confirmed that we now have air flow and that the system is cooling properly. We need to get a new April air model 501 media filter for the model 5000 air cleaner.
Came to call for a leaking duct upon investigation I found that the inline filter for the humidifier had cracked and was leaking on the floor. I isolated the filter. Filter was installed not so long ago need to return to replace filter in warranty.
Removed old Lennox 4-ton coil and condenser. Installed new Coleman 4-ton coil and condenser. Re-hooked up copper to coil and condenser perform pressure test. Pulled vacuum under 200 microns and recharge system. Hooked up. Drain line to condensate pump. Tested condensate pump operational at this time. Re-hooked up heat piping and tested operational at this time. Need to return in the spring to properly test pressures on system. It is approximately 42° outside November 14th 2024 1:38 p.m.
Received a call that the Coleman unit in the attic on the right hand side of the house was not cooling, upon arrival I found that the air filter was plugged solid. Removed the filter media and replaced it with the one that was on top of the air handler, I confirmed that we now have air flow and that the system is cooling properly. We need to get a new April air model 501 media filter for the model 5000 air cleaner.
Arrived onsite for multiple repairs: 1. Replaced humidifier on the heating unit for kitchen area. Confirmed operation of the humidifier 2. Added new water filtration device for the new humidifier 3. Added new water filtration device for humidifier sun room. Confirmed operation of the humidifier. 4. Replaced leaking boiler drain. Confirmed no more leaking. 5. Replaced flue damper motor. Note it is 8” not 6” confirmed operations 6. Replaced failed expansion tank. Homeowner mentioned rattle in kitchen vent. Did not observe any rattle in the system.
Arrived onsite for multiple repairs: 1. Replaced humidifier on the heating unit for kitchen area. Confirmed operation of the humidifier 2. Added new water filtration device for the new humidifier 3. Added new water filtration device for humidifier sun room. Confirmed operation of the humidifier. 4. Replaced leaking boiler drain. Confirmed no more leaking. 5. Replaced flue damper motor. Note it is 8” not 6” confirmed operations 6. Replaced failed expansion tank. Homeowner mentioned rattle in kitchen vent. Did not observe any rattle in the system.
Installed a 4-ton single-speed system, including a Coleman TCD2B48S21S condenser and Coleman XAFC48FBCN1 coil (coil may vary by application). The installation included a standard air filtration system, necessary duct transitions, a new emergency drain pan with an auxiliary switch (for horizontal applications), an EZ Trap condensate trap system (for upflow applications), refrigerant safety caps, and a condenser mounting pad. We flushed and utilized the existing refrigerant piping, reconnected high voltage electric, and completed a full system start-up.
Experience comfort with Comfort Club 8C! Arriving between 11-3? Send an omw text on the way. Update the user. Customer needs help with cooling in the office unit. Book a service on Tuesday afternoons for a stress-free experience.
Experiencing issues with your thermostat in the family room and kitchen? Not getting cool air and feeling the area heating up rapidly? Contact Climate Plus LLC for expert HVAC service. Previous filter plug issue may help diagnose the problem. Customer is aware of service costs.
For prompt HVAC service with After 2pm arrival, look no further than Climate Plus LLC. We recently served Steven and Cole, finding water in the emergency pan of their 3rd floor unit. Call us now for efficient and reliable solutions with no diagnostic charge.
Looking for expert AC repair and installation services for your home? Climate Plus LLC offers quality solutions for all your residential cooling needs. Contact us today for affordable and efficient service.
No arrival time given; "Old blue barn" Customer is reporting system is blowing hot air. This problem started towards the beginning of the week I believe. I also think this unit is on the newer side. (Tim sold the barn to Leah but still leaves there, I spoke with Tim) Tims phone number is (973)270-8938
11-2 Arrival; Non-emergency, Joe asked me to set something up with customer for when he gets back. Correct wiring for basement air handler. When I was on the phone with the customer, he mentioned that we were supposed to be getting back to them about repairing the humidifier, ductwork and setting up for monthly plan. (Special pricing on monthly plan with this customer, 8 syst)
AC Service Call. System running without a call for cooling. Replaced malfunction motor crontrol