JJ was very professional and thorough. He completed the service quickly and checked in with me frequently
Went for a maintenance call today. Started at the air handler, did a static pressure test, it passed. Did a cubic feet per meter count, it met the correct size for the tonnage of the unit. Blower motor amperage passed. When looking at the blower wheel, I noticed it was slightly dirty. Temp split between the return and supply duct passed. Outside unit got washed. The amperage for the compressor and fan motor passed. Thank you for choosing LBA services!
Arrive to customers for AC inspection, And during the inspection we noticed that we have failed CFM count an old furnace with a lot of rust buildup. Seven scheduled for a follow up inspection in August 23 8 AM
Unit was not running when I arrived. Found a blown 3 amp fuse. This system is extremely old r22 system. Also over sized furnace inside. I filter in the return was completely compacted and was no allowing air flow. I replaced 3amp fuse with no filter and system ran fine. I replaced with a 20x25x1 filter an ran the system for close to 45 mins and dropped 5 degrees. If there is future problem we are going to need to look into replacing and getting the right size for this building.