Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are PVC with metal fits that are rusting and allowing sand in the system. Suggest spin cast mortaring the metal then spray lining system with Duct Armor.


Jim D.

Jim D. Job Checkin

Ductwork repair service call. Cleaned system and applied first coat of Duct Armor.


Kevin W.

Kevin W. Job Checkin

10-16-2023: Hydro Jetting service call. descaled/jetted sewer 4” cast sewer. Took measurements in preparation for lining from outside clean out upstream past upstairs stack tie in ending short of old toilet tie in/ vent stack, also downstream to 6” pvc 10-17-2023 • Lined 4” cast iron sewer line through the existing outside clean-out extending approximately 25 feet upstream ending just before the stack in the lower level. Reinstated three connections. Lined 4” sewer line through the existing outside clean out extending downstream approximately 16ft ending in the 6" PVC.


Bob S.

Bob S. Job Checkin

Slab leak repair service call. with video camera inspection. Televised ducts under slab floor. Ducto are PVC ducts with metal fittings that are allowing sand to enter into the system. Sand is also entering through holes in the plenum. Suggest spin cast mortaring to seal the joints and encapsulate the pvc.


Bob S.

Bob S. Job Checkin

Sewer line inspection service call. Televised sewer from outside clean out back into house and out towards pvc. Cast is scaled and channeled on the bottom. Suggest descaling then lining sewer.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections. The ducts look to be in good condition. Looking at the furnace, the ducts under the slab are connected on the return side, so there is never going to be heat or air flowing into that room. Suggest a HVAC professional reconfigure ducts correctly.


Kevin W.

Kevin W. Job Checkin

Customer is experiencing water throughout their underground air duct system. To alleviate this problem, we are installing a perforated sump pump pit next to the furnace to capture the water before it gets into the air ducts. We are also installing drain tile under the furnace and running it to our sump pump to catch more water. We are going to discharge the water out of the left side of the customer’s home.


Bob S.

Bob S. Job Checkin

Video inspection of underground air ducts. Ducts are PVC with metal connections. Water is leaking into air ducts during heavy rains. There was standing water in the main runs and under the furnace. Downspouts need to be extended to reduce the water under the house. After the water issue is resolved the ducts should be spray lined with Duct Armor Duct lining material.