Arrived onsite for maintenance of 2 mini split systems with 5 total head units. Began by cleaning the outdoor condenser coils of each system. Moved inside to the head units where washed the reusable filter for each head unit. Wipe clean of dust each head unit as well. Confirmed cooling operation of each head unit. Observed broken head unit door panel in living unit. Will find out about availability