Arrived to remedy an in operable system. Upon inspection of the system found that the inside portion would turn on but the outside portion would not. Went outside and started diagnosing the condenser. Found that the capacitor is fully failed and is not relay in power to the condenser fan and the compressor. replaced the capacitor to continue diagnostic on the system. Found that the condenser fan motor is failed and will only spin when given a push start. Went inside and inspected the furnace portion of things. Found that the furnace filter was dirty, and the blower wheel is heavily coded in dust debris. Recommend having the furnace fan cleaned in order to ensure proper operation of the system. In order to allow cooling the condenser fan motor needs replaced as well as the 50/5 condenser capacitor. The condenser coil is also in need of cleaning.