Corbin checked everything and replaced a part. Then after he left, called his supervisor to ask his thoughts on the issue before returning and fixing something else.
Jesus and Jacob were prompt and professional. Jesus did an amazing job of explaining the processes and workings of the units. He provided information about how to keep the units working efficiently.
The technician was straight forward and made recommendations. He did not try to oversell his sales pitch. That usually turns me away from a company when they do that.
Heating System Repair: The client’s heating system was not reaching the set temperature. After inspecting the unit, I found the air filter was clogged, restricting airflow. I replaced the filter, enhancing both the efficiency and performance of the system, ensuring reliable warmth.
20 year old r22 system had major repairs completed, credited repairs to new a/c coil. 13.4 seer 2 ton a/c coil going in 7/24/23 with duct and blower cleaning
I’m on arrival I found that the system was not operating. I started testing system and found high static pressure as well as the outdoor unit was not operating due to a trip compressor on overload as well as a bad condenser fan motor. Customer decided to go with repair options and get quotes on replacing the system. After I made repairs, the system is still drying high amps and almost going to freeze up due to low refrigerant.
One leg and the real decision-maker is the wife who is not home. They are price shopping and had Anthony come out. KB complete the next, so I made sure to offer cash discount. They are making decision by tomorrow.
Arrived to do a performance maintenance. Started inspection outside and verified operation of all mechanical and electronic components of the condenser. Found that the capacitor is performing right on the cusp of it allowed variance. Verified system refrigerant charge. Found that the refrigerant readings are skewed by how dirty the coil is. Moved inspection inside and measured a temperature split between return and supply air. Measured power consumption of the blower motor and checked system for cleanliness. Performed a static pressure test and found that the system was operating beyond the rated maximum static pressure. With homeowners approval reached out to the office to schedule a supervisor visit. The supervisor will be able to diagnose the systems high static pressure. Performed a camera inspection of the evaporator coil and heat exchanger and found that the heat exchanger is cracked. This can allow carbon monoxide into the airstream in the home. The supervisor will be able to pr