Patrick  K.

Patrick K.


Job Checkin

Arrived to do a performance maintenance. Set up for combustion analysis temperature split and static pressure tests. Found that the system operating with failing static pressure. Tried to relive enough static pressure to bring the system within manufacturers specifications, but was unable. Set up for a field supervisor to finish the diagnosis on Thursday at 2pm. Verified operation of all mechanical and electronic components of the furnace. Cleaned the flame sensor and retested its performance. Checked blower for cleanliness and to see if there is any play in the bearings. Checked systems heat exchanger to ensure proper venting of flue gas. Found rust present where the heat exchanger is prone to failure. Found lots of debris filling the cracks in the ductwork. Used the inspection camera to look inside the ductwork. Found excessive debris built up inside the ductwork. Furnace is operational at this time.