Responded to a service call regarding a loud noise originating from the outdoor condenser. After a thorough inspection, the noise was traced to a failing condenser fan motor with worn bearings, resulting in excessive vibration and abnormal operation. The system was also found to be low on refrigerant, indicating the presence of a leak that will need to be identified and repaired prior to performing a proper recharge in accordance with manufacturer guidelines. Additionally, the humidifier solenoid is clogged with mineral buildup, restricting water flow and preventing the humidifier from operating as intended. These issues require corrective repairs to restore the system to safe, efficient, and reliable performance. Thank you for choosing LBA Services and for allowing us to care for your home. - Calvin W., Lead Service Technician