Job Checkin

CUSTOMER STATED: they were not having hot water. TECHNICIAN NOTES: called out today to look at a water heater with no hot water. While on site I found the Rheem water heater didn’t not have the serial number or model number sticker on the water heater. You can look at the heater and see where it has been removed. The issue with the hot water heater is the gas control valve. Whenever water heater is being ran the blinking light on the gas control valve stays at 1 blink when means no issue. When no water is being ran through the hot side the gas control valve reads 7 blinks meaning the gas control valve is failed. RESOLUTION/RECOMMENDATIONS: the gas control valve on the Rheem water heater needs replaced or the pilot light will continue to go out. JOB NOTES: hose bibs are off JOB STATUS: NOTCOMPLETE (RETURN TRIP NEEDED?) PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: (AUTHO CODE OR WHO YOU SPOKE TO) ESTIMATES: