2330 Indian Springs Rd
Dudley, NC 28333
(919) 734-9611

Our Top Cities


Job Locations
for williamston, nc


Map of Williamston NC
Romario  T.

Romario T.


Job Checkin

Found compress Pulling 29.2 amps, and is rated for 24amps, Pressures of 466/145psi, high subcool and normal superheat, Condenser fan was pulling 1.8 and is rated for 1.52 amps. Tech adjusted the height of the condenser and assured that the condenser coil was clean in between the inside of the condenser coil by rinsing it with water as best as possible. Tech operated the system back in cooling and after 15-20 minutes, pressures and subcooling went back down to normal ranges, and amp draw on the compressor improved from 29 down to 18-19 amps. Condenser fan amp draw went down from 1.8 to 1.5-1.6 amps. System was cooling upon arrival, Even with abnormal pressures and amp draw ranges. Performance of the system has improved. Jeff C. Approved the repairs for today.