Performed 10-2 furnace tune-up on a 2023 model for new homeowner. Identified and repaired condensate trap leak by cleaning the trap and tightening loose screws around the collector box seal. Completed comprehensive system inspection including filter, blower, heat exchanger and evaporator - all components within specification. Verified proper gas pressures during heating operation with 55° temperature rise during 15-minute operational test.