2930 61st Street
Menomonie, WI 54751
715-283-4422

Our Top Cities


Local Reviews
for baldwin, wi

Rated 4.5 out of 5 stars based on 2 customer reviews

The new faucet looks great

I had Hurlburts out to replace a kitchen faucet, the guy did a great job and really took care to protect our house. Well trained technician and you can tell the company has high standards.


Response from Hurlburt Heating & Plumbing:

We’re so glad you had a good experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Mike is the BEST!

Mike has been coming to my house for over 10 years, he's just a good man that I trust in my home. I wish there were more people like this these days!


Response from Hurlburt Heating & Plumbing:

Thank you for sharing your kind words with us. It means the world to us and to our entire team!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for baldwin, wi

Andrew M.

Andrew M. Job Checkin

Conducted inspection and testing on three ASSE 1013 RPM backflow preventers per reference PO T1154. All Wilkins Zurn devices were accessed through Door 11 and successfully tested, with all three cross connectors functioning properly with no failures or issues identified.

Conducted inspection and testing on three ASSE 1013 RPM backflow preventers per reference PO T1154. All Wilkins Zurn devices were accessed through Door 11 and successfully tested, with all three cross connectors functioning properly with no failures or issues identified. Conducted inspection and testing on three ASSE 1013 RPM backflow preventers per reference PO T1154. All Wilkins Zurn devices were accessed through Door 11 and successfully tested, with all three cross connectors functioning properly with no failures or issues identified.

Koshoua V.

Koshoua V. Job Checkin

Performed comprehensive tune-up on 12-year-old furnace per recurring service agreement. Conducted full inspection including combustion analysis, gas pressure verification, flame sensor/burner cleaning, and heat exchanger evaluation. System is operating normally with no immediate concerns identified; replaced moderately soiled air filter and cleaned pressure switch to ensure optimal performance.

Performed comprehensive tune-up on 12-year-old furnace per recurring service agreement. Conducted full inspection including combustion analysis, gas pressure verification, flame sensor/burner cleaning, and heat exchanger evaluation. System is operating normally with no immediate concerns identified; replaced moderately soiled air filter and cleaned pressure switch to ensure optimal performance. Performed comprehensive tune-up on 12-year-old furnace per recurring service agreement. Conducted full inspection including combustion analysis, gas pressure verification, flame sensor/burner cleaning, and heat exchanger evaluation. System is operating normally with no immediate concerns identified; replaced moderately soiled air filter and cleaned pressure switch to ensure optimal performance.

Trent L.

Trent L. Job Checkin

Replaced faulty single stage control board on furnace. During testing, discovered and remedied an incorrect terminal connection by temporarily wiring blower motor to humidifier terminal to restore heat functionality. Parts order submitted for replacement board to properly complete installation at follow-up service.

Replaced faulty single stage control board on furnace. During testing, discovered and remedied an incorrect terminal connection by temporarily wiring blower motor to humidifier terminal to restore heat functionality. Parts order submitted for replacement board to properly complete installation at follow-up service.

Trent L.

Trent L. Job Checkin

Diagnosed limit switch fault code on 21-year-old furnace. Inspection revealed loose solder joints at limit switch connections on circuit board preventing proper communication. Heat exchanger inspection showed rust accumulation but no immediate failure points. Ordered replacement control board and advised customer that system replacement should be considered within next few years due to unit age and progressive deterioration.

Diagnosed limit switch fault code on 21-year-old furnace. Inspection revealed loose solder joints at limit switch connections on circuit board preventing proper communication. Heat exchanger inspection showed rust accumulation but no immediate failure points. Ordered replacement control board and advised customer that system replacement should be considered within next few years due to unit age and progressive deterioration. Diagnosed limit switch fault code on 21-year-old furnace. Inspection revealed loose solder joints at limit switch connections on circuit board preventing proper communication. Heat exchanger inspection showed rust accumulation but no immediate failure points. Ordered replacement control board and advised customer that system replacement should be considered within next few years due to unit age and progressive deterioration.

Jared R.

Jared R. Job Checkin

Responded to no-heat call for oil-fired Weil-McLain boiler system. Diagnosed multiple issues including low water level in system, disconnected zone valve wire, and noisy circulator pump. Refilled system, reconnected zone valve wiring, and restored heat to residence. Recommended replacement of circulator pump, installation of backflow preventer, replacement of auto fill valve, and updating the aging zone control board. System operational upon departure.

Responded to no-heat call for oil-fired Weil-McLain boiler system. Diagnosed multiple issues including low water level in system, disconnected zone valve wire, and noisy circulator pump. Refilled system, reconnected zone valve wiring, and restored heat to residence. Recommended replacement of circulator pump, installation of backflow preventer, replacement of auto fill valve, and updating the aging zone control board. System operational upon departure. Responded to no-heat call for oil-fired Weil-McLain boiler system. Diagnosed multiple issues including low water level in system, disconnected zone valve wire, and noisy circulator pump. Refilled system, reconnected zone valve wiring, and restored heat to residence. Recommended replacement of circulator pump, installation of backflow preventer, replacement of auto fill valve, and updating the aging zone control board. System operational upon departure.

Kegan M.

Kegan M. Job Checkin

Responded to a service call for a clogged kitchen sink drain. Used drain snake to clear obstruction in the kitchen sink plumbing. Successfully restored proper drainage function after completing snaking procedure.

Responded to a service call for a clogged kitchen sink drain. Used drain snake to clear obstruction in the kitchen sink plumbing. Successfully restored proper drainage function after completing snaking procedure.

Gary L.

Gary L. Job Checkin

Performed standard furnace tune-up on 23-year-old LP system. Unit is operational but showing significant age-related wear with visible corrosion and buildup inside cabinet. Noted non-functional humidifier and customer's regular flame sensor maintenance. Inspected and verified filter condition, which appeared relatively clean. Recommended comfort advisor consultation and humidifier replacement options.

Performed standard furnace tune-up on 23-year-old LP system. Unit is operational but showing significant age-related wear with visible corrosion and buildup inside cabinet. Noted non-functional humidifier and customer's regular flame sensor maintenance. Inspected and verified filter condition, which appeared relatively clean. Recommended comfort advisor consultation and humidifier replacement options. Performed standard furnace tune-up on 23-year-old LP system. Unit is operational but showing significant age-related wear with visible corrosion and buildup inside cabinet. Noted non-functional humidifier and customer's regular flame sensor maintenance. Inspected and verified filter condition, which appeared relatively clean. Recommended comfort advisor consultation and humidifier replacement options.

Bryson E.

Bryson E. Job Checkin

Located and repaired a water leak caused by a nail puncture in the copper supply line. Replaced the damaged section of piping in the utility area behind the washing machine where exposed framing and piping were accessible. Tested the repaired section to ensure proper water flow with no leaks.

Located and repaired a water leak caused by a nail puncture in the copper supply line. Replaced the damaged section of piping in the utility area behind the washing machine where exposed framing and piping were accessible. Tested the repaired section to ensure proper water flow with no leaks. Located and repaired a water leak caused by a nail puncture in the copper supply line. Replaced the damaged section of piping in the utility area behind the washing machine where exposed framing and piping were accessible. Tested the repaired section to ensure proper water flow with no leaks.

Koshoua V.

Koshoua V. Job Checkin

Responded to no heat complaint on older furnace system. Performed comprehensive diagnostic testing of all critical components including flame sensor, pressure switch, limit switch, heat exchanger, and motors. Found no malfunctioning parts; system restored to normal operation after thorough cleaning of components, with indoor temperature successfully raised from 67°F to 72°F.

Responded to no heat complaint on older furnace system. Performed comprehensive diagnostic testing of all critical components including flame sensor, pressure switch, limit switch, heat exchanger, and motors. Found no malfunctioning parts; system restored to normal operation after thorough cleaning of components, with indoor temperature successfully raised from 67°F to 72°F. Responded to no heat complaint on older furnace system. Performed comprehensive diagnostic testing of all critical components including flame sensor, pressure switch, limit switch, heat exchanger, and motors. Found no malfunctioning parts; system restored to normal operation after thorough cleaning of components, with indoor temperature successfully raised from 67°F to 72°F.

Xavier C.

Xavier C. Job Checkin

Diagnosed and serviced a Trane XE 90 furnace (20+ years old) that was blowing cold air with a flashing code. Found a loose electrical harness which was secured to restore heat function temporarily. Identified crack in heat exchanger requiring replacement. Customer scheduled for complete furnace and AC replacement quote as the AC unit had also failed in fall.

Diagnosed and serviced a Trane XE 90 furnace (20+ years old) that was blowing cold air with a flashing code. Found a loose electrical harness which was secured to restore heat function temporarily. Identified crack in heat exchanger requiring replacement. Customer scheduled for complete furnace and AC replacement quote as the AC unit had also failed in fall. Diagnosed and serviced a Trane XE 90 furnace (20+ years old) that was blowing cold air with a flashing code. Found a loose electrical harness which was secured to restore heat function temporarily. Identified crack in heat exchanger requiring replacement. Customer scheduled for complete furnace and AC replacement quote as the AC unit had also failed in fall.

Ben W.

Ben W. Job Checkin

Responded to no-heat call on 10-year-old furnace experiencing intermittent operation. Discovered loose T-wire connection to host relay, which was secured and properly terminated. Adjusted aquastat from 195 to 180 degrees. Observed signs of rust and corrosion in metal ductwork. System tested and verified proper operation upon completion.

Responded to no-heat call on 10-year-old furnace experiencing intermittent operation. Discovered loose T-wire connection to host relay, which was secured and properly terminated. Adjusted aquastat from 195 to 180 degrees. Observed signs of rust and corrosion in metal ductwork. System tested and verified proper operation upon completion.

Ali T

Ali T Job Checkin

Diagnosed 20-year-old Lennox furnace with no heat condition. Identified failed control board and failing capacitor as root causes. Replaced defective components and restored system operation. Provided estimate for future considerations given system age.

Diagnosed 20-year-old Lennox furnace with no heat condition. Identified failed control board and failing capacitor as root causes. Replaced defective components and restored system operation. Provided estimate for future considerations given system age. Diagnosed 20-year-old Lennox furnace with no heat condition. Identified failed control board and failing capacitor as root causes. Replaced defective components and restored system operation. Provided estimate for future considerations given system age.

Trent L.

Trent L. Job Checkin

Diagnosed low pressure issue in aging boiler system causing intermittent heating failure. Discovered malfunctioning backflow preventer preventing proper operation of the auto fill valve. Manually cleared the stuck backflow preventer to restore water flow, properly pressurized the system, and restored heat to the residence. Documented need for replacement of both backflow preventer and auto fill valve as recommended repair.

Diagnosed low pressure issue in aging boiler system causing intermittent heating failure. Discovered malfunctioning backflow preventer preventing proper operation of the auto fill valve. Manually cleared the stuck backflow preventer to restore water flow, properly pressurized the system, and restored heat to the residence. Documented need for replacement of both backflow preventer and auto fill valve as recommended repair. Diagnosed low pressure issue in aging boiler system causing intermittent heating failure. Discovered malfunctioning backflow preventer preventing proper operation of the auto fill valve. Manually cleared the stuck backflow preventer to restore water flow, properly pressurized the system, and restored heat to the residence. Documented need for replacement of both backflow preventer and auto fill valve as recommended repair.

Cody S.

Cody S. Job Checkin

Replaced leaking water heater, relocated unit from corner position, and modified boiler loop piping to facilitate removal of old unit. Observed boiler was non-operational throughout service; scheduled follow-up visit with technician to diagnose and resolve boiler functionality issues. Documented installation with photos of plumbing infrastructure and valve assemblies for record-keeping.

Replaced leaking water heater, relocated unit from corner position, and modified boiler loop piping to facilitate removal of old unit. Observed boiler was non-operational throughout service; scheduled follow-up visit with technician to diagnose and resolve boiler functionality issues. Documented installation with photos of plumbing infrastructure and valve assemblies for record-keeping. Replaced leaking water heater, relocated unit from corner position, and modified boiler loop piping to facilitate removal of old unit. Observed boiler was non-operational throughout service; scheduled follow-up visit with technician to diagnose and resolve boiler functionality issues. Documented installation with photos of plumbing infrastructure and valve assemblies for record-keeping.

Trent L.

Trent L. Job Checkin

Diagnosed intermittent boiler operation due to failing mercury thermostat not consistently sending activation signals. Consulted with homeowner about replacement options and installed new Honeywell Home programmable thermostat. Confirmed proper system operation with boiler now responding appropriately to heating demands.

Diagnosed intermittent boiler operation due to failing mercury thermostat not consistently sending activation signals. Consulted with homeowner about replacement options and installed new Honeywell Home programmable thermostat. Confirmed proper system operation with boiler now responding appropriately to heating demands. Diagnosed intermittent boiler operation due to failing mercury thermostat not consistently sending activation signals. Consulted with homeowner about replacement options and installed new Honeywell Home programmable thermostat. Confirmed proper system operation with boiler now responding appropriately to heating demands.