Completed scheduled furnace tune-up on 17-year-old unit. Identified gas valve leakage and signs of inducer motor failure. Recommended system replacement due to advanced age and multiple critical component issues.
Performed conversion of double vanity plumbing to single vanity configuration. Removed existing double sink setup and reduced water supply and drain connections to accommodate new centered single vanity installation. Properly adjusted supply valves and drain plumbing to ensure proper function and compliance with plumbing code.
Responded to warranty service call regarding an improperly secured condenser unit installed in December. Upon inspection, confirmed wall bracket anchors had released, causing the unit to become unstable and at risk of falling from its wall-mounted position. Completed installation correction form and documented need for install crew to return with proper mounting hardware to secure the condenser safely to the building.
Responded to a service call for a non-functional main water shut-off valve. Inspection revealed the valve was completely frozen in position, preventing proper water control required for city meter replacement. After assessment, scheduled a return visit with city personnel to access the curb stop for complete replacement of the main shut-off valve assembly.
04/07/25 Rob J II Customer has a leak coming from the upstairs tub. We found that the waste and overflow is leaking from the bottom of the tub. Today we replaced the entire brass section of the waste and overflow and reconnected to the original drain piping and trap. Checked for leaks; no leaks were detected.