Completed installation of shower valve and faucet as scheduled return visit. Installed single handle Moen Chateau lavatory faucet with chrome finish, featuring eco-friendly water conservation design. Work involved connecting to existing copper pipe assembly with four-way junction fitting, integrating with the home's water distribution system.
Responded to no-heat call where furnace would not start. Diagnosed issue as clogged pressure switch ports. Performed cleaning of pressure switch ports to restore proper operation of the heating system.
Performed diagnostic assessment of shower valve system with broken handle. Discussed repair vs. replacement options with customer, who ultimately decided to proceed with complete shower valve replacement. Additionally, customer opted to replace lab faucet. Previous quote from another company was noted, but our comprehensive solution was recommended based on accessibility behind shower wall.
Performed scheduled furnace tune-up on recently installed unit. System inspected and confirmed to be operating within normal parameters. Identified and repaired minor leak in PVC exhaust piping to restore proper venting integrity.
Inspected customer's 25-year-old furnace due to concerns about heat exchanger condition. Confirmed previous technician's findings of excessive rust, temperature stress, and wear where pipes connect to the manifold. Observed heat exchanger showing significant stress that presents a potential safety risk but does not yet warrant immediate condemnation. Tested and cleaned flame sensor which showed weak performance (1-1.7 µA). Scheduled service advisor for new furnace estimate and will provide separate estimate for heat exchanger and flame sensor replacement.
Performed comprehensive furnace tune-up service addressing several maintenance issues. Cleaned dirty flame sensor, cleared beehive buildup from fresh air intake/exhaust, replaced dirty filter, and addressed condensation leak at bottom right of furnace. Additionally, adjusted gas pressure on low/high settings, cleared condensation drain line, and verified normal carbon monoxide levels using diagnostic equipment.