Identified and resolved noise issue in HVAC system. Located closed manual damper before basement zone system which was causing whistling sound from supply side during furnace operation. Opened damper to eliminate noise and verified proper system function.
Installed new 40 gallon Bradford White atmospheric water heater in utility room with proper copper piping connections and ventilation system. Completed the installation provided by Hurlburt with all required fittings and ensured proper function of the unit.
Responded to no hot water call for a 14-year-old Richmond natural gas water heater. Diagnostic revealed failed gas valve and leaking temperature and pressure relief valve. Due to unit age, recommended full replacement rather than repair. Customer approved installation of new 40-gallon atmospheric water heater, scheduled for Saturday afternoon.
Replaced 31-year-old water heater that had a compromised tank causing leakage and floor damage in bathroom area. Customer had proactively shut off water supply valve to prevent further leaking. New water heater installed in utility area with proper copper pipe connections and tested for functionality.
Responded to service call for AC not cooling. Diagnosed system with non-functional outdoor fan and inoperative blower motor. Due to unit's age (10+ years) and visible weathering, replaced both failed capacitor and blower motor, successfully restoring cooling operation.
Performed inspection of basement shower valve system per landlord's request. Identified two issues: hot and cold water lines are reversed, and hot water side has restricted flow. Took photographs of the installation and presented replacement options to customer.
Inspected customer's existing Honeywell thermostat system to assess compatibility for smart thermostat upgrade. Evaluated current zone control module with functioning LED indicator and reviewed wiring configuration. Provided consultation on options for upgrading the zoning system as requested.
Performed heating safety inspection on Ruud furnace in response to first call regarding possible cracked combustion chamber and yellow/orange flames. Diagnostic assessment revealed significantly rusted heat exchanger with visible cracks and deterioration, confirming unsafe operating condition. Provided customer with replacement options and estimate for new unit installation.
Performed annual furnace tune-up on 3-year-old Lennox forced air system (Model GX35-30B-6F-20). Found gas valve pressure reading low at 4.6" WC, adjusted down to 1.7" WC. Tested high stage operation after 10-minute wait; attempted to adjust to manufacturer-specified 3.5" WC but valve would not respond to adjustment. Submitted parts request for replacement gas valve as unit appears to be under warranty.