2930 61st Street
Menomonie, WI 54751
715-283-4422

Our Top Cities


Local Reviews
for arkansaw, wi

Rated 5.0 out of 5 stars based on 2 customer reviews

Longtime Customer

It's hard to find good people to work on your house but Hurlburts has always done us right. I like that they always answer their phones, unlike some companies!


Response from Hurlburt Heating & Plumbing:

Thank you so much for your 5-star review!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good service, not cheap though

They showed up on time and did a really good job replacing my shower valve, the plumber was really sharp and he told me exactly what he was doing along the way. They aren't cheap, but definitely good.


Response from Hurlburt Heating & Plumbing:

Thank you for the wonderful review and for taking the time to share your feedback.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for arkansaw, wi

Gary L.

Gary L. Job Checkin

Performed routine maintenance on 27-year-old Goodman 90% efficiency furnace. Inspection revealed cracked heat exchanger inside burners, which was previously replaced approximately 10 years ago. Due to safety concerns with the compromised heat exchanger, recommended complete system replacement.

Performed routine maintenance on 27-year-old Goodman 90% efficiency furnace. Inspection revealed cracked heat exchanger inside burners, which was previously replaced approximately 10 years ago. Due to safety concerns with the compromised heat exchanger, recommended complete system replacement. Performed routine maintenance on 27-year-old Goodman 90% efficiency furnace. Inspection revealed cracked heat exchanger inside burners, which was previously replaced approximately 10 years ago. Due to safety concerns with the compromised heat exchanger, recommended complete system replacement.

Mike B.

Mike B. Job Checkin

Responded to a sold repair for a Lennox Model AFU 85 oil furnace to replace a defective single stage control board. Upon inspection, identified additional issues with the air adjustment mechanism affecting proper flame control. Determined that specialized parts may be unavailable for this aging unit and recommended customer consult with sales advisor regarding potential oil furnace replacement options.

Responded to a sold repair for a Lennox Model AFU 85 oil furnace to replace a defective single stage control board. Upon inspection, identified additional issues with the air adjustment mechanism affecting proper flame control. Determined that specialized parts may be unavailable for this aging unit and recommended customer consult with sales advisor regarding potential oil furnace replacement options.

Mike B.

Mike B. Job Checkin

Responded to customer complaint regarding excessive noise from 5-year-old Train furnace during startup. Conducted comprehensive inspection including scope examination of heat exchanger which showed no issues. Identified severe rusting on burners and potential combustion blower problems. Provided customer with replacement options for deteriorated components to resolve the noise issue.

Responded to customer complaint regarding excessive noise from 5-year-old Train furnace during startup. Conducted comprehensive inspection including scope examination of heat exchanger which showed no issues. Identified severe rusting on burners and potential combustion blower problems. Provided customer with replacement options for deteriorated components to resolve the noise issue. Responded to customer complaint regarding excessive noise from 5-year-old Train furnace during startup. Conducted comprehensive inspection including scope examination of heat exchanger which showed no issues. Identified severe rusting on burners and potential combustion blower problems. Provided customer with replacement options for deteriorated components to resolve the noise issue.

Beca R.

Beca R. Job Checkin

Responded to no heat call for LP-fueled furnace. Diagnosed multiple system failures including stuck gas valve preventing fuel flow to burners and out-of-specification capacitors for both blower motor and inducer. Scheduled follow-up appointment with advisor to address additional concerns with inducer and blower motor showing damage from capacitor issues.

Responded to no heat call for LP-fueled furnace. Diagnosed multiple system failures including stuck gas valve preventing fuel flow to burners and out-of-specification capacitors for both blower motor and inducer. Scheduled follow-up appointment with advisor to address additional concerns with inducer and blower motor showing damage from capacitor issues. Responded to no heat call for LP-fueled furnace. Diagnosed multiple system failures including stuck gas valve preventing fuel flow to burners and out-of-specification capacitors for both blower motor and inducer. Scheduled follow-up appointment with advisor to address additional concerns with inducer and blower motor showing damage from capacitor issues.

Beca R.

Beca R. Job Checkin

Performed scheduled maintenance on 8-year-old ICP model FG9MXE furnace. Completed comprehensive tune-up including flame sensor cleaning, electrical testing (all components within specifications), and heat exchanger inspection with no compromises detected. Verified drain lines clear and system functioning properly.

Performed scheduled maintenance on 8-year-old ICP model FG9MXE furnace. Completed comprehensive tune-up including flame sensor cleaning, electrical testing (all components within specifications), and heat exchanger inspection with no compromises detected. Verified drain lines clear and system functioning properly. Performed scheduled maintenance on 8-year-old ICP model FG9MXE furnace. Completed comprehensive tune-up including flame sensor cleaning, electrical testing (all components within specifications), and heat exchanger inspection with no compromises detected. Verified drain lines clear and system functioning properly.

Mike B.

Mike B. Job Checkin

Replaced the first main burner unit in an Empire gas heater located in the greenhouse. Installation was successful with proper operation verified during post-repair testing. Additional scheduled work for furnaces, humidifiers, and garage heaters has been postponed due to time constraints.

Replaced the first main burner unit in an Empire gas heater located in the greenhouse. Installation was successful with proper operation verified during post-repair testing. Additional scheduled work for furnaces, humidifiers, and garage heaters has been postponed due to time constraints.

Mike B.

Mike B. Job Checkin

Performed routine LP furnace tune-up on 10-15 year old system. Inspection revealed critical safety issues including cracked heat exchanger with visible holes in side. Unit was tagged out of service due to safety concerns. Service advisor dispatched to discuss replacement options with customer.

Performed routine LP furnace tune-up on 10-15 year old system. Inspection revealed critical safety issues including cracked heat exchanger with visible holes in side. Unit was tagged out of service due to safety concerns. Service advisor dispatched to discuss replacement options with customer. Performed routine LP furnace tune-up on 10-15 year old system. Inspection revealed critical safety issues including cracked heat exchanger with visible holes in side. Unit was tagged out of service due to safety concerns. Service advisor dispatched to discuss replacement options with customer.

Ethan S.

Ethan S. Job Checkin

Completed comprehensive furnace tune-up with inspection of all critical components. System is operating within specifications with proper heat exchange (65° temperature rise) and no compromises found in the heat exchanger. Verified condensate drainage, checked pressure readings (623-626), and confirmed multi-stage cycling is functioning correctly. Noted filter is due for replacement soon, but blower assembly is clean and properly balanced.

Completed comprehensive furnace tune-up with inspection of all critical components. System is operating within specifications with proper heat exchange (65° temperature rise) and no compromises found in the heat exchanger. Verified condensate drainage, checked pressure readings (623-626), and confirmed multi-stage cycling is functioning correctly. Noted filter is due for replacement soon, but blower assembly is clean and properly balanced. Completed comprehensive furnace tune-up with inspection of all critical components. System is operating within specifications with proper heat exchange (65° temperature rise) and no compromises found in the heat exchanger. Verified condensate drainage, checked pressure readings (623-626), and confirmed multi-stage cycling is functioning correctly. Noted filter is due for replacement soon, but blower assembly is clean and properly balanced.

Mike B.

Mike B. Job Checkin

Diagnosed inoperative greenhouse LP heater following customer report of fuel outage. Disassembled unit, identified heavily corroded and damaged burner assembly requiring replacement. Submitted order request for new Empire heater burner components and steam humidifier canisters for follow-up service.

Diagnosed inoperative greenhouse LP heater following customer report of fuel outage. Disassembled unit, identified heavily corroded and damaged burner assembly requiring replacement. Submitted order request for new Empire heater burner components and steam humidifier canisters for follow-up service. Diagnosed inoperative greenhouse LP heater following customer report of fuel outage. Disassembled unit, identified heavily corroded and damaged burner assembly requiring replacement. Submitted order request for new Empire heater burner components and steam humidifier canisters for follow-up service.

Paul M.

Paul M. Job Checkin

Water Heater Repair: Went out to repair a water heater that was not producing hot water. I found that the heating element was not working properly. I replaced the heating element and the water heater was working properly again.


David B.

David B. Job Checkin

I was called to a house to repair a furnace that was not working. I arrived and found that the furnace was not getting any power. I checked the circuit breaker and found that it was tripped. I reset the breaker and the furnace started working again. The customer was pleased with the service.


David B.

David B. Job Checkin

Fix AC


David B.

David B. Job Checkin

Check for carbon monoxide


Dean M.

Dean M. Job Checkin

Replace water heater in Arkansas


Paul M.

Paul M. Job Checkin

Serviced furnace