Repaired kitchen sink leak by replacing faulty basket strainers and continuous waste assembly. Removed deteriorated P-trap and installed new components to resolve drainage issues. All connections were tested and confirmed watertight with proper seals at fixture penetrations.
Responded to no heat call for aging furnace. Gas valve was not engaging despite receiving 24V signal. After manual agitation of the valve and testing with multimeter, successfully restored furnace operation temporarily. Customer informed that gas valve requires replacement but opted to wait for scheduled service advisor visit for replacement quotes. Customer has alternative heating sources available if system fails before repair.
Replaced furnace burner assembly on 25-year-old HVAC system that was experiencing intermittent heating issues. Job required 2 hours of labor with parts sourced from Meno. Customer expressed interest in system replacement, and a follow-up appointment was scheduled to discuss options.
Completed furnace repair by replacing burner assembly. Successfully installed new burners, verified proper operation, and confirmed appropriate gas pressure. All systems now functioning correctly.
Responded to service call for non-functioning garage heater. Diagnosed multiple issues including a faulty sequencer failing to send 120V to indoor fan despite receiving 27V across the coil, and a loose solder connection on the control board. During troubleshooting, the control board experienced an electrical short. Unit requires replacement of both control board and sequencer for proper operation.
Diagnosed no heat issue on aging Amana 90 Air Command furnace, last serviced in 2019. Discovered severely rusted burners impeding proper gas flow, performed thorough cleaning of accessible components to restore temporary operation, and ordered replacement burner assembly to ensure reliable heating function.
Responded to no-heat call for 15-year-old furnace. Diagnosed seized inducer motor and found broken drain kit leaking water and exhaust fumes into furnace cabinet. Provided customer with repair options for inducer motor, drain kit, and thermostat replacement, along with replacement furnace option for comparison. Customer will review options before deciding on repair versus replacement.
Responded to customer complaint of furnace cycling issues. Performed diagnostic testing on LP furnace (2000 model) and monitored operation through complete heat cycle. Identified condensate drainage problem with current setup requiring manual emptying of collection bucket; documented system condition with photographs for future replacement estimate consideration.
Responded to no-heat call for a 13-year-old Goodman furnace system. Upon arrival, customer reported intermittent operation with heat working overnight but failing during inspection. Diagnosed thermostat communication issues after multiple power cycling attempts and battery verification. Installed new Honeywell T4 ProSeries thermostat to resolve the intermittent control problem and verified proper system operation before departure.
Diagnosed Lennox furnace with insufficient heating issue. Identified severely clogged air filter restricting proper airflow, causing furnace to short cycle and fail to meet heating demand. Replaced filter, restored proper airflow, and verified system now operating at normal heating capacity.
Responded to no-heat call on recently installed Lennox furnace system. Diagnosed issue with concentric fresh air/exhaust roof jack that had frozen, causing pressure switch to trip and system shutdown. Modified venting configuration by terminating the exhaust vent and routing exhaust through the fresh air vent per supervisor's recommendation to resolve the issue.
Responded to no heat call for 10-year-old furnace that was intermittently starting then shutting off. Diagnosed severely rusted burners restricting gas flow. Performed thorough cleaning of burner assembly to restore proper flame pattern and ignition sequence. Submitted parts order for replacement components to ensure reliable operation.
Diagnosed furnace with no heat issue exhibiting Error Code #1 for pressure switch. Found failed high limit switch and incorrect 10 amp fuse in control board. Installed temporary high limit switch rated at 250° and replaced with proper 3 amp fuse, confirming the limit switch was causing the fuse to blow. Submitted order for permanent replacement switch.
Diagnosed 2016 furnace with no heat issue. Inspection revealed a damaged control board, failed ignitor, and malfunctioning blower motor. System showed significant airflow restriction due to missing air filters, resulting in contaminated evaporator coil and blower wheel. Prepared detailed estimate for component replacement and cleaning services for customer consideration.
Replaced outdated two-handle shower valve with new Moen chrome model. Installed complete valve assembly with proper copper and brass connections, ensuring secure mounting to wall structure. Reconnected shower head and verified system functionality after installation.