Responded to service call regarding inoperative Nest thermostat and furnace issues on a 2018 Bryant system. Diagnosed blown 3-amp fuse in furnace control board caused by improper thermostat installation. Replaced fuse, restored system functionality, and educated customer on proper procedure to turn off power when replacing thermostat in the future.
Installed customer-supplied bathroom and kitchen faucets in 1979 home to address multiple leaking fixtures. Completed full toilet installation with associated plumbing work including new shut-offs. Also performed hot water line service and disposal-related plumbing while re-piping various connections to ensure proper functionality.
Performed routine maintenance on a 12-year-old natural gas furnace. Inspected all components including electrical connections, gas pressure, flame sensor, igniter, and condensate lines; all were in good working condition. Unit is operating properly with no issues identified.
Performed scheduled furnace tune-up on approximately 10-15 year old unit. Conducted combustion analysis testing using UEi C161 analyzer with readings of O2 15.1%, CO 11p, and CO2 3.3%. Identified and replaced dirty air filter to improve system efficiency and airflow. Noted two long nails near starter and fuel source which were addressed during service.
Performed scheduled furnace tune-up on 12-year-old FRP unit for Family Rewards member. Identified faulty gas valve and dirty filter; completed maintenance by replacing gas valve and documenting with photos of control board and condensate drainage system components.
Responded to callback service request for thermostat displaying error code 53. Inspected and secured all wiring connections at thermostat and control board, verified proper voltage readings throughout system. Performed comprehensive diagnostic testing including heat exchanger inspection, which revealed rust buildup on one heat exchanger eyelid. Carbon monoxide levels and gas pressure (both low and high) tested within acceptable safety parameters. Informed homeowner about heat exchanger condition and explained that thermostat lacks reset functionality for the specific error code.
Disconnected dishwasher to facilitate flooring replacement following kitchen flood damage caused by ice maker line leak. Installed new water supply line for refrigerator ice maker with proper connection to prevent future leakage issues. Access required navigation through confined utility chase to properly route copper supply line.
Performed comprehensive inspection on 10-15 year old tanked water heater located in compact utility closet. System includes copper plumbing network with circulation pump and multiple valve connections. Provided client with maintenance recommendations and replacement estimates due to unit's advanced age, though no immediate operational issues were identified.
Performed scheduled furnace tune-up on 17-year-old FRP system. Inspected customer's water heater that was experiencing short cycling and ignition failure. Provided replacement options for the aging water heater (10+ years old) which shows visible rust at the bottom.
Diagnosed and replaced failed thermostat on 12-4 Lennox system (approximately 10 years old) that was experiencing no cooling issues and going into system waiting mode. Performed electrical testing with digital multimeter to verify proper voltage readings before installation. Customer advised about replacement options as system has reached end of expected service life.
Performed inspection of 11-year-old 50-gallon power vent natural gas water heater. Discussed replacement options with customer, providing estimates for 50-gallon power vent, 75-gallon power vent, and tankless water heater systems as requested by customer who expressed interest in converting from tanked to tankless configuration.
Returned to customer's residence to reposition towel bar in kitchen sink cabinet that was inadvertently placed behind garbage disposal during previous installation. Successfully removed and reinstalled towel bar in front of disposal unit to restore proper functionality and access.
Conducted an HVAC system assessment after customer reported AC freeze-up issue. Inspection revealed aging furnace unit with compromised ductwork connections and condensate line problems. Recommended full system replacement based on observed component deterioration, improper installation markings, and ventilation concerns that are likely contributing to the cooling malfunction.
Responded to service call for non-functioning garbage disposal. Upon inspection, removed existing unit and installed new garbage disposal model. Connected all plumbing components, including proper P-trap configuration and drain assembly. Verified system operation and confirmed no leaks in the newly installed components.
Diagnosed R22 system from 1997 with no cooling issue due to significant ice buildup on evaporator coil and refrigerant line. Performed R22 recharge to restore temporary cooling function. Identified aging system (25+ years) with deteriorating components; scheduled comprehensive system replacement estimate for Thursday morning.