Replaced outdated plumbing components in kitchen, including installation of new water shut-off valve and supply line for dishwasher connection. Removed existing disposal unit and installed new garbage disposal with proper connections to sink drain system. All systems tested and functioning properly after service.
Performed geothermal system maintenance per membership agreement. Diagnosed system locked out on low pressure fault code. Tested pressure sensor continuity and performed board jump test - both confirmed control board failure rather than actual low pressure condition. Arranged for replacement control board to be ordered through Parts department, noting potential warranty coverage.
Performed annual maintenance on two residential heating systems: 10-year-old boiler and 11-year-old furnace under rewards membership program. Disassembled and cleaned ultra boiler heat exchanger in main house, replaced customer-supplied humidifier water panel and filters. Restored disconnected thermostat to proper operation. At cottage, serviced furnace by cleaning flame sensor and condensate components, and performed standard boiler maintenance without disassembly as inspection indicated minimal fouling. All systems verified operational upon completion.
Performed annual furnace tune-up on 1-year-old FRP unit. Identified and repaired condensate leak at trap by applying silicone. Noted severely dirty filter (unchanged for over 1 year), advised customer to replace. All electrical components tested within specifications, heat exchanger inspected with no compromises found. Verified proper LP gas pressures with 45-degree temperature rise and confirmed normal system operation after repair.
Responded to no-heat service call for older fuel oil furnace (10+ years). Upon arrival, found unit disassembled by customer with broken porcelain on electrodes. Conducted assessment and completed parts order form for electrodes, recommending replacement of ignitor and nozzle along with a complete tune-up. Customer was advised of service recommendations and parts availability limitations due to system age.
Performed routine maintenance on 6-year-old Goodman furnace per agreement. Replaced dirty filter, verified clean and balanced blower with capacitor within specifications. Inspected heat exchanger (no compromises found), verified clear routing lines, and tested system operation. Confirmed proper gas pressure with 70° temperature rise during 15-minute operational test. All components functioning normally.
Responded to a no-heat call for a 6-7 year old Goodman LP forced air furnace displaying lockout code. Diagnostic testing revealed the furnace was attempting ignition (igniter lighting and gas valve opening) but failing to sustain operation due to excessive start retries. Inspection identified severely corroded and plugged burners as the primary issue. Heat exchanger was thoroughly examined with no compromises found. Performed immediate service by removing and cleaning burners to restore temporary heat. System tested successfully with 40° temperature rise and operated normally for 15 minutes without issues. Recommended replacement burners (to be ordered) due to extensive corrosion, and provided customer with estimate for this future service.
Performed standard boiler tune-up and identified non-functioning bedroom zone pump requiring replacement. Replaced pressure switch during service call. System inspection revealed absence of isolation valves on pump, necessitating full system drain for future pump replacement. Replacement pump pricing and follow-up service to be scheduled.
Responded to no-heat complaint for a 10+ year old furnace system. Diagnostic testing confirmed failed igniter with proper voltage from control board. Inspected heat exchanger for cracks/damage and verified blower components. Provided customer with repair options for igniter replacement and discussed replacement possibilities for both furnace and AC units. Service call completed with follow-up appointment scheduled.
Responded to no heat call for 10+ year old LP furnace. Diagnosed and repaired burnt wiring connections to blower motor using new adapter connectors, restoring system operation. Noted significant cracking of burner plate and advised customer that equipment is approaching end of useful life; provided quote for replacement furnace as requested.
Completed maintenance service on Goodman forced air LP gas furnace. Performed comprehensive inspection including heat exchanger evaluation with no defects found. Cleaned flame sensor and condensate system; furnace is in good overall condition with no operational issues identified.
Responded to emergency no-heat call where customer reported smoking and flames inside their aging boiler. Investigation revealed combustion issues caused by insulation material that had been pulled into the burner orifice area by a rodent, preventing proper burning. Removed insulation debris, performed standard boiler service, and cleaned flame sensor to restore proper operation. System functioning normally upon departure but recommended replacement of pilot assembly if intermittent pilot issues persist.
Completed annual maintenance tune-up on 17-year-old high-efficiency Munchkin boiler system. Identified one leaking pipe in the hydronic distribution network requiring repair. Provided customer with requested quotes for boiler replacement, duct cleaning, and water softener installation due to aging equipment condition. Referred to comfort advisor for follow-up on upgrade options.
Performed semi-annual maintenance on Lennox heat pump system per Family Rewards agreement. Conducted complete tune-up on electric heat and heat pump components with all electrical connections testing within specifications. Replaced dirty filter, verified proper operation in both standard and emergency heat modes with acceptable temperature rises (40° and 45° respectively), and inspected indoor air handler and outdoor condensing unit with no issues found.
Performed comprehensive furnace tune-up service on residential system. Inspection revealed clean filter and proper gas pressures with temperature rise of 45 degrees. Noted blower wheel accumulating dirt with mechanical play; all electrical components including capacitor tested within specifications. Heat exchanger inspection showed no compromises. System tested and monitored for 20 minutes with normal operation. Customer informed about blower motor condition and future repair recommendations.