Responded to no heat call at residence with LP furnace. Found unit was switched off; restored power and verified operation, though evidence of limit switch activation observed due to heavily clogged filter. Discovered entire house was frozen including plumbing fixtures; thawed frozen condensate trap to restore proper drainage and temporarily disconnected frozen condensate pump. Advised customer to reconnect pump upon return and noted potential for significant plumbing issues once thawing occurs.
Responded to no-heat call for a 4-month-old Lennox heating system. Diagnostic inspection revealed frozen vent pipe causing system failure. Corrective action taken: cut off affected section of vent pipe and verified proper furnace operation, restoring heat to residence.
Responded to no-heat call on 25-year-old Gibson LP furnace. Diagnosed multiple component failures including inoperative blower motor that hummed but wouldn't spin, failing gas valve, and heavily soiled burners. Customer had previously attempted repair by replacing ignitor without success. Comprehensive evaluation conducted with circuit board inspection. Recommended complete system replacement due to advanced age and multiple critical component failures.
Inspected 4-year-old furnace failing to reach high-stage operation despite thermostat being set to 70°F with actual home temperature at 55°F. Determined root cause to be severe airflow restriction due to improper evaporator coil box installation, where the coil was placed inside a pre-existing box causing the SLP furnace to operate at only 70% capacity. Documented installation issue with photos for further consultation with management regarding remediation options.
Completed installation of two toilets with new wax rings, bolt kits, supply lines, and cap sets. Replaced tank-to-bowl gasket on master toilet. Connected drain and supply lines for two lavatory faucets and one laundry faucet, ensuring proper function and no leaks.
Performed complimentary tankless water heater descaling service and heat exchanger flush. System inspection revealed components in good condition. Discussed water treatment options with homeowner and scheduled water care advisor consultation for the following week.
Performed scheduled preventative maintenance on late-model Daikin furnace system. Conducted comprehensive inspection with no issues detected; equipment in excellent condition with clean internal components. Provided customer with replacement air filter as part of regular rewards maintenance agreement.
Responded to no hot water complaint affecting upstairs shower only. Inspected chrome faucet valve assembly and determined faulty cartridge preventing proper temperature regulation. Provided estimate for cartridge replacement to restore normal hot water function to shower while maintaining existing functionality at lavatory sink.
Responded to no heat complaint but identified actual issue was isolated to hot water supply in upstairs bathtub, not boiler-related. Verified water heater operational with both elements functioning properly and confirmed hot water available at other fixtures. Issue diagnosed as plumbing fixture problem; arranged for qualified plumber to address bathtub fixture repair.
Inspected oil furnace after customer reported soot throughout house following service by another company. Found incorrect nozzle size had been installed previously, causing extensive soot accumulation in mechanical room, clean-outs, burn chamber, and chimney. Tagged out and shut down furnace due to safety hazards from improper venting through baro damper. Advised customer that heat exchanger replacement would be required and recommended chimney cleaning; scheduled consultation for gas furnace conversion options.
Responded to no-heat call for 10-year-old LP boiler system displaying ignition fault/lockout. Discovered severely plugged heat exchanger which was cleaned as part of a maintenance kit installation. After cleaning, identified and resolved combustion issues likely caused by either gas mixture changes following recent LP tank filling or previous throttle screw adjustment. Made necessary throttle screw adjustments to properly calibrate combustion on both low and high fire. Verified proper system operation for 20 minutes with stable ignition and performance restored.
Responded to customer complaint of furnace not maintaining desired temperature. Inspected Lennox system, verifying LP supply, checking components, ensuring proper condensate drainage, and confirming clear venting. Observed slightly dirty filter but determined this was likely not causing the issue. After 20-minute test run, system operated without problems. Installed customer's new filter and advised to monitor for recurrence.
Responded to no heat emergency call. Diagnosed faulty control board in furnace system as evidenced by visual inspection of circuit components. Submitted parts order form for replacement control board to restore heating functionality.
Responded to service call for leaking 80-gallon electric water heater (2023 Home Depot model). Determined unit was not repairable. Installed ball valve on cold water supply line to enable isolation of the water heater. Documented electrical panel configuration and existing plumbing setup with photographs. Recommended replacement with appropriate commercial model electric water heater.
Responded to no heat complaint at customer's café. Diagnosed York furnace showing fault code 57 (pressure switch failure) that persisted even in fan-only mode. Found severely clogged 14x14x1" filter that customer was unaware of, significant water accumulation around unit from leaking water heater, and evidence of multiple previous repairs. After unsuccessful attempts to jump terminals and power the blower with 24V, customer was advised to contact plumber for water heater leak and schedule follow-up for either component replacement or full system replacement consultation.