Diagnosed and provided estimate for toilet flange repair using a 4x3 inside fit flange to replace corroded existing flange. Customer purchased HOROW one-piece toilet; proposed complete toilet installation after cutting out damaged flange section.
Replaced leaking 2017 A.O. Smith electric water heater that showed significant tank corrosion and floor staining at base. Customer accepted replacement estimate after inspection confirmed tank failure. Also inspected toilet with intermittent leak history, which had previously resolved itself.
Responded to no-cool complaint for 7-8 year old AC system with tripped breaker. Diagnostic testing revealed a drained capacitor on fan side while compressor tested good. Replaced defective capacitor, reset breaker, and verified proper system operation by checking refrigerant levels, wiring, and coil. System restored to normal cooling function.
Performed routine tune-up on 14-year-old Ruud furnace system which was operational upon arrival. Diagnosed non-responsive Honeywell thermostats on second and third levels; discovered disconnected red wire and restored connectivity. Main level thermostat (newer Honeywell with color display) was functioning properly. System now operating correctly with balanced temperature control across all zones.
Performed scheduled furnace tune-up per Family Rewards agreement. Conducted comprehensive system inspection including combustion analysis with normal CO readings, proper gas pressure verification, and air exchanger examination. All connections were secured and system is operating normally with no issues detected.