Performed comprehensive furnace tune-up on 10-year-old Amana unit. Detected leaking from collector box, cleared condensate lines, and replaced air filter. Inspection revealed secondary heat exchanger failure with visible joint leakage. Documented issue with digital imaging and provided warranty information to homeowner. Scheduled follow-up service for heat exchanger replacement.