2930 61st Street
Menomonie, WI 54751
715-283-4422

Our Top Cities


Job Locations
for durand, wi


Map of Durand WI
Trevor P.

Trevor P.


Job Checkin

Diagnosed ignition failure on IBC boiler serving shop heating system. Verified spark igniter functioning properly but identified faulty gas valve preventing fuel flow. Temporarily restored operation by manually actuating solenoid during ignition sequence. Completed parts order form for replacement gas valve after confirming unit is out of warranty.

Diagnosed ignition failure on IBC boiler serving shop heating system. Verified spark igniter functioning properly but identified faulty gas valve preventing fuel flow. Temporarily restored operation by manually actuating solenoid during ignition sequence. Completed parts order form for replacement gas valve after confirming unit is out of warranty.