Responded to no heat emergency for 60-year-old natural gas furnace. Discovered failed gas valve and suspected crack in heat exchanger with visible corrosion and deterioration documented in inspection photos. Due to safety concerns and age of system, recommended immediate replacement rather than repair; scheduled advisor follow-up to discuss replacement options.