Performed ac maintenance on an ac & mini split. Replaced capacitor in Goodman & added 1lb 410 to mini split
Performed ac maintenance on 2 acs. Completed maintenance checklists. Replaced capacitor in goodman
Performed ac maintenance. Completed maintenance checklists.
Arrive, went to thermostat. It was calling for AC, with the furnace checked filter filter was dirty. Left filter out blower was running, went to condenser found. Compressor was running, but fan was not, found capacitor bad replaced capacitor sprayed off coil turned back on unit checked pressures had a 18° split.
Arrived, found that unit was frozen, checked if fan was working the fan was barely working, check control board found it wasn’t sending enough power to motor need new control board and motor could be bad when control board is replaced
Arrive, check temp drop and we had a 20° temp drop, found that blower motor was on a low speed put it to the high speed, went to top floor and 58° coming out of supply vent
Repaired wiring to capacitor on York system. Cleaned both condenser coils. R22 system is low after cleaning coils. Sent estimate to replace older carrier system. York system is cooling good now. Pressures were good. Temp inside is at 68.
Performed ac maintenance. Completed maintenance checklists. Labor & material for adding half lb 410 & replacement capacitor
Ran camera through furnace heat exchanger and burner tubes several holes in exchanger recommending roofing company for chimney caps approximately 45-50 feet up.
During the recent maintenance visit, we conducted a thorough evaluation of the air conditioning system. We initiated the session by inquiring about any specific concerns the customer might have had. The condition of the furnace filter and evaporator coil was assessed, and we recorded the blower amp draw. We also ensured proper airflow by inspecting the cleanliness of the condenser coil outside. Additionally, we examined the electrical components of the condenser for any signs of burnt or loose wires and verified the microfarad readings on the capacitor. Finally, we confirmed that the refrigerant pressures were within the correct range to guarantee optimal system performance.
Installed 1 customer supplied shower head and removed old lav faucet and pop up. 1 faucet will not work for the sink it goes in and other shower head missing parts. Will buy new faucet.