I am a highly skilled home service professional. I recently completed a heating maintenance job for a client. The job included cleaning the flame sensor, spark igniter, air filter, and combustion burners. I also verified that the heat rise was good and that the humidifier should be turned on when temperatures start dropping to experience full quality heat.
I was called to replace a faulty element in a customer's home. After inspecting the appliance, I determined that the element needed to be replaced. I removed the old element and installed a new one, ensuring that it was properly connected and functioning. I tested the appliance to ensure that it was working correctly before leaving the customer's home.
I am a highly skilled home service professional with over 10 years of experience in the industry. I recently completed a job for a client who needed to order a replacement part for their dishwasher. The part was a heating element, and I ordered it from the manufacturer's website. I then installed the new heating element and tested it to ensure it was working properly. The client was very pleased with the work I performed, and I was happy to have been able to help them get their dishwasher back up and running smoothly.
We have completed your maintenance after my inspection I determined the system to be low on 410 a I topped unit off and temp split is at 20 be for filling unit I was only getting a 15 degree temp split
Refrigerant levels couldn’t be better, ac is running great, we are dealing with a ductwork issue, the crawlspace ductwork isn’t insulated and picking up all the humidity and pushing it back through the home, we only have 64 degrees coming from the vents and there’s no room the crawlspace for work to be done… I’d consider calling a general contractor to get the flooring up to get into the crawlspace easier and seeing if they are able to get to the crawlspace and ductwork.
Customer stated he changed out blow capacitor, and then his thermostat started acting weird. came out and found that his transformer was blown. Replaced transformer system was up and cooling. Customer said he’d like to talk about possible replacement come this fall.
Wired in new stat wire and all 3 modes system is working. No issues with fuse popping.
Warranty: NEED AARON TO RETURN TO REPLACE THE DEFROST CONTROL BOARD FOR HEAT PUMP. DEFROST CONTROL BOARD IS UNDER WARRANTY. COLLECT PAYMENT FOR LABOR WHEN COMPLETE. Customer still having issues isolated the problem to the indoor stat wire. Wire ohmed out fine but was still having issues. Bypassed stat wire and ran tstat directly off the furnace without any issues. Informed homeowner about the problem he said he will try to pull a new wire. If he's unable to an installe crew needs to return.
Defrost board was shorted out between B and common which damaged the tstat and blew the fuse. Installed april air stat and disconnected h.p. until we return with the new defrost board.
NEED AARON TO RETURN TO REPLACE THE COMPRESSOR AND LINE DRIER FOR HEAT PUMP. COMPRESSOR IS UNDER WARRANTY. COLLECT PAYMENT WHEN COMPLETE. Replaced compressor and tstat. Ran system through all 3 modes everything is working great.
Spoke to customer upon arrival. Expressed concern about multiple leaks in faucets. Also expressed concern about sump pump pit. Was not able to detect any leak in master bath sink. Found that head in faucet for laundry is completely clogged. Customer stated that he will put it in vinegar to see if it fixes. I was able to clean out aerator and tighten up handle on kitchen faucet. Found that sump pump pit in basement is a 5 gallon bucket and is causing the sump pump float to get stuck on side of bucket. Also found that softener was not fully set up. Customer does not know how long softener was installed Gave customer estimates for replacing some pump pit with proper pit. Replacing sump pump. Replacing softener and adding iron filter onto softener. Customer stated that he wants to call original installer of softener.
Fuse blown again. Ohmed out low voltage again no issues replaced fuse and unit cycled without tripping. Disconnected h.p. low voltage temporarily to see if it resolves the issue.
Flushed tank and replaced customer provided canister filter.
Removed old duel fuel controller and cleaned up old wiring and multiple splices at the furnace and cycled system multiple times without any issues with the low voltage. Customer stated h.p. breaker started to trip over winter. Inspected unit and found the compressor windings are open and the compressor will need replaced.
Unit not running thermostat didn’t have any power. Found 3 amp fuse blown. Replaced fuse and unit ran. Turned thermostat off and system was still running heat. Found wires behind thermostat rubbing together. Rewired thermostat and unit ran properly.