Rated 5.0 out of 5 stars based on 2 customer reviews

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job . The Tech was very professional and Theral.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for circleville, oh

Khyrenn F.

Khyrenn F. Job Checkin

Ac maintenance everything checked out good


Khyrenn F.

Khyrenn F. Job Checkin

Ac maintenance everything checked out good


Zach S.

Zach S. Job Checkin

Topped off unit with 4 ounces of R134a


Trevon S.

Trevon S. Job Checkin

Plumbing maintenance. Asked if there were any concerns. Checked water pipes for leaks. Checked condition of t&p valve. Flushed sediment out of tank. Radon test read 2.43pci


Trevon S.

Trevon S. Job Checkin

Plumbing maintenance. Asked if there were any concerns. Checked water pipes for leaks. Checked condition of t&p valve. Flushed sediment out of tank. Radon test read 1.43pci


Calob B.

Calob B. Job Checkin

Furnace has a bad inducer


Preston R.

Preston R. Job Checkin

Performed furnace maintenance. Completed maintenance checklist, cleaned blower housing, cleaned flame sensor, took amp draws, took temp split, & checked filter


Preston R.

Preston R. Job Checkin

Performed furnace maintenance. Completed maintenance checklist, cleaned blower housing, checked amp draws, cleaned flame sensor, took temp split, & changed filter.


Dustin  W.

Dustin W. Job Checkin

This is an estimate to replace heat pack. The part is roughly 2-3 business days out and available for install upon arrival. If you would like to have this work performed please accept the estimate and we will get this scheduled. Thanks Ron


Brad H.

Brad H. Job Checkin

Cleaned condenser. Checked air filter. Checked and adjusted dampers and supply vents. System is working correctly now.


Alan  M.

Alan M. Job Checkin

System is tripping breaker in heat mode needs new heat pack


Ron M.

Ron M. Job Checkin

Condensing coil full of debris causing system to go out on high pressure. Cleaned coil system is operating as it should


Steve S.

Steve S. Job Checkin

Drain coming off the evaporator coil was completely clogged up. Took drain off cleaned out drain completely dried out. Blower compartment. System is up and working properly.


Zach S.

Zach S. Job Checkin

NEED TO RETURN TO REPLACE THE CONTROL BOARD FOR FURNACE. COLLECT PAYMENT WHEN COMPLETE.


Zach S.

Zach S. Job Checkin

Internal control fault. System will kick ac on when jumped. Relay is shorted and keeping inducer motor in at all times. Unable to diagnose further until control board is replaced, may have more issues