Spent 3 days without heat and had horrible communication. Advertised 24-hour service and didn't offer after work hours. Missed 3 days of work.
Steve was very thorough, professional, and skilled. Great job.
Completed ac looks great no issues found
Completed ac looks great no issues found
NEED JAYDEN TO RETURN TO REPLACE THE CONTROL BOARD FOR FURNACE. COLLECT PAYMENT WHEN COMPLETE.
Replaced capacitor and added a hard start. Amp draws normal pressures are good. Cooling works.
System empty on arrival. Ductwork is insufficient for 3 tons of cooling. Ac unit will need replaced a Ductwork reworked.
Unit is in need of a new control board , we will send over pricing on it Thanks
NEED TO SEND AARON BACK TO REPLACE THE EVAPORATOR COIL AND INSTALL A TXV FOR A/C UNIT. PARTS AND LABOR ARE UNDER WARRANTY. NO CHARGE FOR REFRIGERANT. NO CHARGE TO CUSTOMER. Evaporator coil needs reworked along with plenum. Coil is pushed to far forward allowing air to bypass the backside of coil. Coil is temporarily taped until we can return for repairs.
NEED SWONGER TO RETURN TO REPLACE TXV. TECH WILL NEED TO BACK UP THE REFER INTO THE COMPRESSOR AND USE EXISTING REFER. TXV IS UNDER WARRANTY. COLLECT PYMENT WHEN COMPLETE. Changed out TXV and line dryer had an 18° temp split and was still going down. System is working properly.
Check blower speed and static pressures no issues found. The txv is stuck and not metering refrigerant.