Performed furnace tune-up maintenance on 24-year-old system that was running noisily before winter season. Cleaned flame sensor, checked air filter, and inspected heat exchanger where two significant cracks were discovered in one of the cells. Informed homeowner of findings, who acknowledged the issue and expressed interest in system replacement quotes as the equipment has reached end of service life.