228 E Main St
Newark, OH 43055
740-345-6639

Our Top Cities


Local Reviews
for orient, oh

Rated 5.0 out of 5 stars based on 5 customer reviews

Great service

Trevon was quick and efficient!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Dave did a great job! He was on time for the appointments, kept updated on his arrival time and was quick and efficient in his work.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Doug and Will did a quick and efficient job of installing the new heat pump arriving on time; they made quick work of the install.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service

Dave Atha demonstrated deep product knowledge, answering all my questions thoroughly. This led me to purchase a heat pump from them. Both Dave and the finance assistant, April, were very responsive throughout the process.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service


Response from Dor-Mar Heating & Air Conditioning:

Thank you for the 5 star review, Mike!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for orient, oh

Trevon S.

Trevon S. Job Checkin

Ac not cooling. Checked operation of system. Found condenser coil dirty cleaned coil and hooked up gauges. Found unit to be low on r22. Used customer’s r22 to add charge to system. System is up and running.


Preston R.

Preston R. Job Checkin

Performed ac maintenance. Completed maintenance checklists.


Trevon S.

Trevon S. Job Checkin

Ac maintenance. Asked if there were any concerns. Checked condition of furnace filter and evaporator coil. Took reading of blower amp draw. Checked for clean condenser coil outside to ensure proper airflow. Checked electrical on condenser for any burnt or loose wires. Checked mfd readings on capacitor. Made sure refrigerant pressures read correctly.


Nathan W.

Nathan W. Job Checkin

This is an estimate to replace igniter on fuel oil system. Unfortunately the parts needed are obsolete and unavailable. We can try to retrofit a new igniter in the system. If you would like to have this done please accept the estimate and we will get this scheduled. Thanks. Transformers we took would not work. Was able to find transformer online. Will order and return. Returned with correct transformer. Installed. Burner lit up and is running smooth.


Ron M.

Ron M. Job Checkin

Found ignition transformer not sparking and nozzle plugged. Replaced nozzle. Will send estimate to replace ignition transformer. Ignition transformer is obsosolete. Sent over estimate to try and retrofit a new fit a new design to unit. Tried calling with no answer. If they have any questions they can give me a call


Nathan W.

Nathan W. Job Checkin

declined parts advised restock fee


David A.

David A. Job Checkin

Found inducer port clogged bad. Customer wants to hold off on replacing Bvent piping. Radon Level below 4.


Ron M.

Ron M. Job Checkin

Parts are ordered will be tomorrow/wednesday


Mack  M.

Mack M. Job Checkin

Replaced nozzle and filter. Burner now running as it should. Need to send estimate to replace downstairs circulating pump.


Trevon S.

Trevon S. Job Checkin

During our visit, we performed [a thorough maintenance service on your furnace]. This involved [meticulously addressing the buildup on the flame sensor]. Additionally, we conducted [detailed assessments of the amp draw of both the blower motor and inducer motor]. Furthermore, we carefully inspected the condition of the heat exchanger, ensuring that it met all required standards. In addition, we checked ohms on hot surface igniter to guarantee its proper functioning. Lastly, we tested the overall operation of the system to ensure optimal performance.


David A.

David A. Job Checkin

No failing parts on the 2017 Lennox mid efficient up flow furnace. Cleaned the flame sensor, unit was clean inside, amp draws on both motors are in spec along with ohms on the igniter. Order of operations happened in the proper sequence & the system is operating optimally with a clean filter and new humidifier pad. Advising a Uv Light air purifying application.


Skyler C.

Skyler C. Job Checkin

I scheduled the customer's yearly furnace maintenance for their Orient, Ohio home.


Zach S.

Zach S. Job Checkin

Not cooling in fresh food section. Weak cooling in freezer. Found evap fan motor not running. Verified voltage on motor. Motor is NLA, unit is 30 years old. Need to contact for price to install unit. Cabinet opening is 70inches wide and 66 and a half tall. Single unit is 33 inches wide and double unit is 66 inches. NYU438


Trevon S.

Trevon S. Job Checkin

Heating maintenance for electric heat. Checked amp draw on blower motor, breaker, and heating elements. Checked operation of system. Checked condition of filter. Checked supply air temperature


Trevon S.

Trevon S. Job Checkin

Unit not cooling. Hooked up gauges and pressures were extremely low. Checked evaporator coil and coil was filthy. Also found dead ferret in evap coil. Removed ferret and spayed evap coil with no rinse spray. Ferret messed up insulation inside cased evap coil. Hooked up gauges and pressures were still off. Recommend replacing evaporator coil or replacing ac system. Emailed estimates over.