Performed scheduled bi-annual furnace maintenance on two Amana units. Services included cleaning flame sensor, testing electrical components, verifying clear drain lines, and conducting combustion analysis (CO 25P, CO2 9.0%, XAIR 52.8%) - all readings within specifications. Filter was relatively new and did not require replacement. Both furnaces are operating properly with no issues detected.