Installed owner provided toilet seat & shower head in master bathroom. Ran tests on both units after install. No leaks or loose. Installed 2” flapper in guest bathroom in basement due to old flapper failing. After install ran tests. No leaks.
Material and labor to install new hot water recirculation pump with separate recirculation line back to water heater for kitchen. Total Installed Price $1324
Found leaking from branch wye and dishwasher drain hose. Cut out plumbing under kitchen sink. Old disposal sat too low for plumbing. Replaced garbage disposal and replumbed under kitchen sink. Ran medium machine down drain to unclog. Filled sink up twice with water. Drains properly and no leaks.
Shut off valve was leaking in second bathroom on the right. Replaced shut off valve and supply tube. Tested no leaks.
Found water being held from build up in pipe from stack behind bathroom in storage room to main clean out, but before floor drain in utility room no backup seen, backing up into shower drain. Ran large machine out to clear, ran camera saw build up on black iron pipe 15-22’, ran 3” offset bit out out to 24’, then 3” c bit out to 50’, ran camera out to 60’, looks good. Ran water hose from water heater to help flush out debris, showed customer rusty pipe, and build up now removed but needing more flushing and water use to get out of pipes.
Installed new 75 gallon power vent water heater. Connected to existing gas, water, and vent as needed. Tested, no leaks. 10 year parts, 2 year labor warranty. Set for 120 degrees. Invoice paid in full on 4/10/25 service call.
Customer is selling condo and all the handles are broke. Off of angle stopsCut out both kitchen sink stops, both lav sink stops, and toilet stops installed all with new, Reconnected all supply lines and checked for leaks. No leaks
Inspected water on the floor. It is coming from the 75 gallon water heater power vent. We then did a water test. She is getting soft water but the hardness was set wrong. It was set to low at 24,000. We bumped it up to 32,000 grain of hardness. Everything should be good at that part.
We installed a new 3” flapper in the master bathroom toilet and a new Bradford White 75-gallon natural gas power vent water heater with a 10-year warranty.
Fill valve blew out causing water to constantly run. Replaced with action supplied fluid master fill valve. Reconnected to existing braided supply line. After install, ran tests. No leaks. Recommend to customer replacing 1 piece flush valve to prevent any further issues from occurring.
Put strain relief on garbage disposal and fix neutral double taps in panel. Everything tested and functional when I left.
Replace kitchen faucet with action supplied single hole moen faucet. Replace basket strainer, one foot of dishwasher hose and traps under kitchen sink on left side. Tested no leaks.
Installed 50 gallon natural gas power vent water heater with hot return line and new ball valve. Comes with two years parts and labor warranty then 8 years on parts and tank warranty.
Estimate to run a 240 V feed to garage for electric car charger.