David B.

David B.


Job Checkin

Callback for no heat. Found unit sooted up. Cleaned electrodes, nozzle, and adjusted electrodes. System fired up. After runtime of 30 minutes, found high levels of CO leaking into home. 15PPM of CO out of bedroom registers - unsafe operation. Turned unit off and informed customer. Will have Ian from Pat’s Heating contact customer for replacement options. Thanks Mike. Note: Ian will be in touch as soon as possible.

Callback for no heat. Found unit sooted up.  Cleaned electrodes, nozzle, and adjusted electrodes.  System fired up.  After runtime of 30 minutes, found high levels of CO leaking into home. 15PPM of CO out of bedroom registers  - unsafe operation. Turned unit off and informed customer. Will have Ian from Pat’s Heating contact customer for replacement options. Thanks Mike. 

Note: Ian will be in touch as soon as possible.