AC clean and check prepaid. New 16x25x4 filter also left one spare so 2 total. 45/7.5 capacitor checks good. Amp draw was 3.05 New hose. Subcool should be 10 checked out at 10. All else are within factory specifications. Run test everything running fine at this. Communicated with homeowner on findings.