Install 2ton Daikin mini split in garage with lineset, communication wires, pad, Uv protections, drain line and line hide. Pressure test up 300 psi and bubble test for leaks. Vacuum the unit down 114 microns and let it stand for more than 10mins. Test the drain line with water. Test unit for heat and cool mode. Unit is currently working.